Comparative design of harmonic current reduction in variable speed drive using space vector pulse width modulation and hybrid pulse width modulation Siregar, Yulianta; Situmeang, Farel; Mohamed, Nur Nabila
International Journal of Electrical and Computer Engineering (IJECE) Vol 14, No 5: October 2024
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijece.v14i5.pp4907-4920

Abstract

In industry and commerce, three-phase induction motors are frequently utilized as the primary power source for machinery. However, to increase motor performance efficiency, induction motors also need a tool for speed control. The variable speed drive (VSD) is one tool used to control the rotation speed of three-phase induction motors. Since VSD is a non-linear load, harmonic distortion will result from it. The space vector pulse width modulation (SVPWM) injection method and the hybrid pulse width modulation method were the two techniques employed by the author in this study to lower the current in the VSD. With the SVPWM injection approach, the variable speed drive's current total harmonic distortion (THD) values in the R, S, and T phases dropped to 3.77%, 3.53%, and 2.19% from 7.14%, 7.17%, and 7.58%.
Comparison design of dynamic voltage restorers, distribution static compensators and unified power quality conditioner series shunts on voltage sag, and voltage swell Siregar, Yulianta; Mubarok, Syahrun; Mohamed, Nur Nabila
International Journal of Electrical and Computer Engineering (IJECE) Vol 15, No 2: April 2025
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijece.v15i2.pp1396-1410

Abstract

One issue with the power system is electrical power quality, which is brought on by short circuit disruptions and growing nonlinear loads. Power systems frequently have short circuits, resulting in voltage sags that can harm delicate loads. Voltage sage and swell issues can be resolved using unified power quality conditioner series shunts (UPQC-S), distribution static compensators (DSTATCOM), and dynamic voltage restorers (DVR). Custom power devices are very useful in overcoming problems with electrical networks. In this research, due to 3-phase short circuit faults, voltage sag and swell simulations were conducted using a load equal to 70% of the total load and a fault location point of 75% of the feeder length, from the results of research conducted with the case study PT. PLN (Persero) UP3 Sibolga Feeder SB 02 shows that DVR performs better than DSTATCOM and UPQC-S in handling voltage sag and voltage swell due to 3-phase short circuit disturbances. The DVR succeeded in providing the largest voltage sag recovery in phase C, increasing the voltage from 0.2481 pu to 0.9776 pu. The DVR is also effective in overcoming voltage swell on phase A, reducing it from 1.724 pu to 0.9969 pu.
Comparative analysis of active filters, inductor-capacitor and inductor-capacitor-inductor passive filters in reducing harmonics Siregar, Yulianta; Azhari, Naomi; Mohamed, Nur Nabila
International Journal of Electrical and Computer Engineering (IJECE) Vol 15, No 3: June 2025
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijece.v15i3.pp2567-2582

Abstract

Control equipment at substations requires a rectifier to convert alternative current (AC)-direct current (DC) electric current to provide DC power for relays, motors for disconnector switches and power breaker switches, and telecommunications equipment. Rectifiers have non-linear load characteristics, which can result in a waveform that is not pure sinusoidal due to the interaction of fundamental frequency sinusoidal waves with other waves known as harmonics. Therefore, to not interfere with the equipment's work, a filter is needed to reduce the harmonics produced by the rectifier. In this research, using MATLAB/Simulink, prevention was carried out using active filters, inductor-capacitor (LC), and inductor-capacitor-inductor (LCL) passive filters (Ta, Tc, and Td designs) separately. After the research was carried out, it was found that the amount of harmonics before installing the filter was 49.61%. Then, after installing the active filter, the harmonics were reduced to 0.29%, the installation of the passive LC filter was reduced to 9.29%, and the installation of the LCL filter (Ta, Tc, and Td) became 1.44%, 0.29%, and 1.44%.