Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : Jurnal Ilmiah Teknik Elektro

MODEL VEKTOR TEGANGAN DALAM MODULASI VEKTOR RUANG 3-DIMENSI PADA FILTER AKTIF SISTEM TIGA-FASA Indriarto Yuniantoro; Ishak Kasim
Jetri : Jurnal Ilmiah Teknik Elektro Jetri Volume 13, Nomor 1, Agustus 2015
Publisher : Website

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (477.579 KB) | DOI: 10.25105/jetri.v13i1.564

Abstract

Anelectric current flow on the neutral wire give raise to harmonics. It is a problem that must be solved one of which is space vector modulation technique. A few voltage vector models have been developed including by Zhang and Perales. In this paper the models are compared to determine reference voltage vector and duty cycle, developed asymmetric’s model based on Akagi theory too. The results show that asymmetric’s model can be proposed as a new technique in space vector modulation.Arus yang mengalir pada kawat netral menimbulkan harmonisa. Hal itu merupakan masalah yang harus diselesaikan salah satunya adalah dengan teknik modulasi vektor ruang. Beberapa model vektor tegangan telah dikembangkan diantaranya oleh Zhang dan Perales. Dalam tulisan ini dibandingkan model-model tersebut dalam menentukan vektor-tegangan referensi dan duty cycle. Dikembangkan pula model asimetri yang berdasarkan pada teori Akagi. Hasilnya menunjukkan bahwa model asimetri dapat diusulkan sebagai satu teknik baru dalam modulasi vektor ruang.
PENGATURAN ARUS KOMPENSASI UNTUK PEMBEBANAN NONLINIER PADA SISTEM FILTER AKTIF TIGA FASE Indriarto Yuniantoro; Rudy S. Wahyudi
Jetri : Jurnal Ilmiah Teknik Elektro Jetri Volume 14, Nomor 2, Februari 2017
Publisher : Website

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2171.32 KB) | DOI: 10.25105/jetri.v14i2.1605

Abstract

The nonlinear load connected to a three-phase currents source will cause distortion. In order to reduce the distortion, a three-phase active filter system is used. Reduction is carried by the compensation current. The proportional integral (PI) control is often used to control the compensation current. Development of pulse width modulation rectifiers connected to the PI control can produce a pure sinusoidal current source. Compensating current control is also done by Akagi instantaneous power theory approach. Beban nonlinier yang dihubungkan dengan arus sumber tiga fase akan mengakibatkan distorsi. Untuk dapat mereduksi distorsi tersebut digunakan filter aktif sistem tiga fase. Reduksi dilakukan dengan mengkompensasi arus. Dalam pengaturan arus kompensasi digunakan kendali proporsional integral (PI). Pengembangan kendali PI terhubung penyearah modulasi lebar pulsa (MLP) menghasilkan arus sumber sinusoida murni. Pengendalian arus kompensasi dilakukan juga dengan pendekatan teori daya sesaat Akagi.