Katsuyuki Yamaoka
Ritsumeikan University

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : TELKOMNIKA (Telecommunication Computing Electronics and Control)

Simultaneous Electrochemical Measurement using Paper Fluidic Channel on CMOS Chip Jun Eguchi; Katsuyuki Yamaoka; Shigeyasu Uno
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 15, No 2: June 2017
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v15i2.6131

Abstract

This paper described the new system of biosensing using CMOS chip. The system was expected to be used in various circumstances because it was suitable for miniaturization compared to the conventional system. To conduct electrochemical measurements, the new system used paper fluidic channel set on the CMOS chip to transport solution to the on-chip electrodes. The materials of paper fluidic channel were only paper and silicone resin, and these were biocompatible. In experiment, we carried out simultaneous detection of glucose and ethanol in liquid sample solutions on the 5mm square CMOS chip and paper fluidic channel. Furthermore, this system can detect various target molecules in addition to glucose and ethanol, and increase number of simultaneous measurement by adding some more process to the paper and CMOS chip. 
Potentiometric Glucose Detection by Paper-based Electrochemical Sensor on CMOS Chip Katsuyuki Yamaoka; Jun Eguchi; Shigeyasu Uno
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 15, No 2: June 2017
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v15i2.6129

Abstract

This paper presents a low cost portable medical device for biochemical sensor using CMOS chip and paper-based fluidic channel. We measured a potential produced by enzyme activity of glucose between the working and reference electrode on CMOS chip. A liquid sample is transported by paper-based fluidic channel, which is made of chromatography paper and silicone resin, and consists of the area for filtering a sample (filter layer) and that for reacting enzyme (enyzme layer). The paper-based fluidic channel is used by combining CMOS chip, and the solution with glucose is dropped from top of the paper-based fluidic channel. The concentrations of glucose are detected by potentiometry (open circuit potential time). The experimental results show that the glucose concentration is measured by CMOS chip and paper-based fluidic channel.