Saidatul Norlyana Azemi
Universiti Malaysia Perlis

Published : 5 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : Indonesian Journal of Electrical Engineering and Computer Science

Structural Health Monitoring Sensor based on A Flexible Microstrip Patch Antenna Hamse Abdillahi Haji Omer; Saidatul Norlyana Azemi; Azremi Abdullah Al-Hadi; Ping Jack Soh; Mohd Faizal Jamlos
Indonesian Journal of Electrical Engineering and Computer Science Vol 10, No 3: June 2018
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v10.i3.pp917-924

Abstract

A microstrip patch antenna strain sensor operating at dual frequencies 1.8GHz and 2.4GHz have been designed based on the relation between the resonant frequency and the strain applied to it. Felt substrate with a height of 3mm and dielectric constant of 1.44 and shield conductor are used for the design of this antenna. Testing results show that the resonant frequency of the microstrip patch antenna is 1.78 GHz and 2.4 GHz, which agrees with the simulation. The resonant frequency of the microstrip patch antenna increases linearly with the increase of the applied strain. This microstrip patch antenna strain sensor can be integrated with other components easily and have a great potential applications in structural health monitoring systems.
FBG sensor strain performance analysis using optisystem software too Muhammad Imaduddin Mohd Razi; Mohd Rashidi Che Beson; Saidatul Norlyana Azemi; Syed Alwee Aljunid
Indonesian Journal of Electrical Engineering and Computer Science Vol 14, No 2: May 2019
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v14.i2.pp564-572

Abstract

Fibre Bragg Grating is an optical fibre that widely use as sensor to sense strain, temperature and pressure. The advantages of FBG sensor are it will not affected by electromagnetic interference which can improve the accuracy of the result and also can be wearable sensor. In this paper, Optisystem software tools are used to analyse the strain performance of FBG sensor for monitoring knee joint movement in rehabilitation process. Single mode FBG with original wavelength of 1550nm are used to get the accurate result because of less attenuation and absorption factor. This project also analysed the wavelength shifted when strain experienced by FBG change. The accuracy of sensor and method of delivering the result are taken into the account. The interrogator are used to display the wavelength shifted by the FBG when there is change in strain experienced by FBG. All of the proposed designed are tested by using simulation software and the wavelength shifted in the simulation are compared to the theoretical value that has been calculated in this project. The development of this system expected to improve the rehabilitation process towards a healthy life.