Claim Missing Document
Check
Articles

Found 5 Documents
Search
Journal : Al-Fiziya: Journal of Materials Science, Geophysics, Instrumentation and Theoretical Physics

Analisis Nilai Fraksi β Dari Film Tipis Polimer Komposit PVDF/Fe3O4 Terhadap Konsentrasi Fe3O4 Gizelda Larasati Anindita; Ambran Hartono; Ryan Rizaldy
Al-Fiziya: Journal of Materials Science, Geophysics, Instrumentation and Theoretical Physics Al-Fiziya: Journal of Materials Science, Geophysics, Instrumentation and Theoretical Physics | Vol.3
Publisher : Physics Study Programme, Faculty of Science and Technology UIN Syarif Hidayatullah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15408/fiziya.v3i1.15020

Abstract

AbstrakFilm tipis telah dibuat dengan mengompositkan PVDF yang berperan sebagai matriks dan Fe3O4 yang menjadi pengisi dengan menggunakan metode celup sederhana. Penelitian ini dilakukan dengan pengujian XRD setiap sampel dengan 4 variasi konsentrasi 2%, 4%, dan 6% dari Fe3O4 untuk diketahui pengaruh konsentrasi Fe3O4 terhadap nilai fraksi
Sintesis dan Karakterisasi Barium Heksaferit dengan Variasi Pengurangan Massa Fe2O3 Ryan Rizaldy; Sitti Ahmiatri Saptari; Wisnu Ari Adi
Al-Fiziya: Journal of Materials Science, Geophysics, Instrumentation and Theoretical Physics Al-Fiziya: Journal of Materials Science, Geophysics, Instrumentation and Theoretical Physics | Vol.1
Publisher : Physics Study Programme, Faculty of Science and Technology UIN Syarif Hidayatullah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (548.693 KB) | DOI: 10.15408/fiziya.v1i2.9504

Abstract

Barium Heksaferit berhasil disintesis dengan menggunakan metode solid state reaction, dalam upaya untuk menghasilkan fase yang tunggal, kami melakukan pengurangan massa dari Fe­2O3. Dimana kami mengurangi dengan komposisi tertentu, kami menggunakan faktor pengurangan x dengan variasi x = 1, 2, 3, dan 4. Hasil dari sintesis di karakterisasi menggunakan XRD untuk melihat fase-fase apa saja yang terbentuk. Hasil data XRD kami analisis menggunakan metode penghalusan Rietveld, dan mendapakan hasil dimana berkurangnya komposisi pengotor (dalam hal ini Fe2O3) pada hasil sintesis seiring dengan pengurangnya massa bahan baku Fe2O3
Portable Water Quality Measurenment System for Sanitation Muhamad Fauzan Zarkashie; Elvan Yuniarti; Ryan Rizaldy
Al-Fiziya: Journal of Materials Science, Geophysics, Instrumentation and Theoretical Physics AL-FIZIYA JOURNAL OF MATERIALS SCIENCE, GEOPHYSICS, INSTRUMENTATION AND THEORETICAL PHYSICS VOL.5, N
Publisher : Physics Study Programme, Faculty of Science and Technology UIN Syarif Hidayatullah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15408/fiziya.v5i2.24708

Abstract

ABSTRACTWater is one of the essential needs that play an essential role in supporting life on earth. Water for sanitary hygiene purposes is used for several things to maintain individual hygiene, such as bathing and toothbrushes. Water is also for washing foodstuffs, tableware, and washing clothes. In addition, water for hygiene sanitation can be used as raw water for drinking water. This research designs a water quality measurement tool using parameters following water quality for sanitary hygiene purposes issued by the Ministry of Health. These parameters include turbidity, acidity (pH), temperature, and solids in water. The tool is designed to use Arduino Uno as a controller, sensors according to the parameters of photodiode sensors, pH, temperature, TDS (Total Dissolved Solids), and output systems using an LCD 20 x 4. This study concluded that the water quality detection system is running well, using photodiode sensors that can read each level of turbidity based on the value of ADC (Analog Digital Converter). The TDS sensor has an accuracy rate of 93.2% with a 6.8% error percentage. The pH sensor has an occurrence rate of 97.5% with a 2.5% error percentage, and a temperature sensor has an accuracy of 97.84% with a 2.16% error percentage.
Portable Water Quality Measurenment System for Sanitation Muhamad Fauzan Zarkashie; Elvan Yuniarti; Ryan Rizaldy
Al-Fiziya: Journal of Materials Science, Geophysics, Instrumentation and Theoretical Physics AL-FIZIYA JOURNAL OF MATERIALS SCIENCE, GEOPHYSICS, INSTRUMENTATION AND THEORETICAL PHYSICS VOL.5, N
Publisher : Physics Study Programme, Faculty of Science and Technology UIN Syarif Hidayatullah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15408/fiziya.v5i2.24708

Abstract

ABSTRACTWater is one of the essential needs that play an essential role in supporting life on earth. Water for sanitary hygiene purposes is used for several things to maintain individual hygiene, such as bathing and toothbrushes. Water is also for washing foodstuffs, tableware, and washing clothes. In addition, water for hygiene sanitation can be used as raw water for drinking water. This research designs a water quality measurement tool using parameters following water quality for sanitary hygiene purposes issued by the Ministry of Health. These parameters include turbidity, acidity (pH), temperature, and solids in water. The tool is designed to use Arduino Uno as a controller, sensors according to the parameters of photodiode sensors, pH, temperature, TDS (Total Dissolved Solids), and output systems using an LCD 20 x 4. This study concluded that the water quality detection system is running well, using photodiode sensors that can read each level of turbidity based on the value of ADC (Analog Digital Converter). The TDS sensor has an accuracy rate of 93.2% with a 6.8% error percentage. The pH sensor has an occurrence rate of 97.5% with a 2.5% error percentage, and a temperature sensor has an accuracy of 97.84% with a 2.16% error percentage.
Sintesis dan Karakterisasi Barium Heksaferit dengan Variasi Pengurangan Massa Fe2O3 Ryan Rizaldy; Sitti Ahmiatri Saptari; Wisnu Ari Adi
Al-Fiziya: Journal of Materials Science, Geophysics, Instrumentation and Theoretical Physics Al-Fiziya: Journal of Materials Science, Geophysics, Instrumentation and Theoretical Physics | Vol.1
Publisher : Physics Study Programme, Faculty of Science and Technology UIN Syarif Hidayatullah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.15408/fiziya.v1i2.9504

Abstract

Barium Heksaferit berhasil disintesis dengan menggunakan metode solid state reaction, dalam upaya untuk menghasilkan fase yang tunggal, kami melakukan pengurangan massa dari Fe­2O3. Dimana kami mengurangi dengan komposisi tertentu, kami menggunakan faktor pengurangan x dengan variasi x = 1, 2, 3, dan 4. Hasil dari sintesis di karakterisasi menggunakan XRD untuk melihat fase-fase apa saja yang terbentuk. Hasil data XRD kami analisis menggunakan metode penghalusan Rietveld, dan mendapakan hasil dimana berkurangnya komposisi pengotor (dalam hal ini Fe2O3) pada hasil sintesis seiring dengan pengurangnya massa bahan baku Fe2O3