S. A. Osman
Department of Civil and structural Engineering, Universiti Kebangsaan Malaysia

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : Civil Engineering Journal

Utilization of Hybrid SIFCON to Improve Performance and Properties of Slab System Openings Abuzaid, Esraa Kh.; Osman, S. A.; Mutalib, Azrul A.; Al-Zaidee, Salah R.
Civil Engineering Journal Vol 10, No 11 (2024): November
Publisher : Salehan Institute of Higher Education

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.28991/CEJ-2024-010-11-07

Abstract

This research aims to enhance Slurry Infiltrated Fibrous Concrete (SIFCON) by incorporating both long and short fibers, with the goal of increasing ductility and mechanical properties behavior. The study also evaluates the effectiveness of SIFCON in strengthening two-way reinforced concrete slabs with large openings. Various SIFCON mixes were created, integrating hooked-end fibers, micro steel fibers, and different volume ratios (Vf) of hybrid steel fibers (one-third, one-half, and two-thirds). A reference mix with 2% hybrid fiber-reinforced concrete (SFC) was formulated for comparison. Hybrid SIFCON samples demonstrated superior mechanical properties compared to those reinforced with hooked fibers, showing higher compressive strength, cylinder compressive strength, flexural strength, and direct tensile strength by 14%, 13.9%, 38.2%, and 58.2%, respectively, at 28 days, but a lower splitting tensile strength by 24%. Compared to micro steel fiber-reinforced samples, hybrid SIFCON exhibited higher compressive strength, cylinder compressive strength, flexural strength, and splitting tensile strength by 18.2%, 51%, 167.5%, and 43.6%, respectively, but a lower direct tensile strength by 7.4%. The study involved nine two-way square slabs with various mixtures of normal concrete, mortar-infiltrated fiber concrete, and full SIFCON. Control samples were constructed using normal-strength concrete. The application of SIFCON increased punching shear strength by 3.21% to 154.25% compared to the control samples. Doi: 10.28991/CEJ-2024-010-11-07 Full Text: PDF
Flexural Behaviour of Precast Lightweight Concrete Sandwich Slabs With Demountable Bolted Steel Shear Connectors Al-Kerwei, Rana H.; Osman, S. A.; Al-Zand, Ahmed W.; Hanoon, Ammar N.
Civil Engineering Journal Vol 11, No 2 (2025): February
Publisher : Salehan Institute of Higher Education

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.28991/CEJ-2025-011-02-06

Abstract

A concrete slab is a fundamental element and contributes the highest weight in structural buildings. In this paper, a new type of sandwich slab consisting of two layers of lightweight concrete and demountable steel connectors is proposed in a new attempt to reduce the weight of the floors within the structure and apply a simpler and faster approach to connecting the layers of sandwich panels. The structural effects of the proposed connectors on Precast Lightweight Concrete Sandwich Slab (PLCSS) are evaluated experimentally and theoretically in terms of strength, stiffness, degree of composite action, and usability for floor construction. The behaviors of six PLCSS specimens subjected to four-point loads were investigated, studying the effects of varied parameters such as different numbers, arrangements, and shapes of demountable steel connectors (I, V, and X connector shapes) fastened with steel bolts, in addition to one solid concrete slab as a reference specimen. The panels' performance in this structural system was evaluated by measuring the degree of composite action using load, displacement, stress, and neutral axis methods. Based on the experimental results, the slab panels exhibited composite panel behavior until the point of failure. Under flexural loads, the panel behaved similarly to that of a solid one-way slab; crack patterns appeared in one direction. The specimens with IC, VC, and XC showed different load capacity values, ranging from 22.74 kN to 50.55 kN; these values depend on the types of shear connectors and their numbers in the sandwich panels. Using V and X connectors enhances the composite action between layers, increasing the shear demand and making the shear failure more likely. It can be concluded that demountable shear connectors can transfer shear between the two concrete wythes, resulting in a composite panel with structural integrity, a lighter weight, and satisfying ACI specifications for floor applications. Doi: 10.28991/CEJ-2025-011-02-06 Full Text: PDF