Performance based design of Hospital Building in Surabaya under variety design alternative using SNI 1726-2019 – Case study: Redesign Building Sigit Darmawan; Raden Buyung Darmawan; Ridho Bayuaji; Yuyun Tajunnisa; Indra Komara; Sita Auliyah Rahmasari
IPTEK The Journal of Engineering Vol 9, No 2 (2023)
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j23378557.v9i2.a16231

Abstract

Nowadays, At the present time, the occurrence of regular earthquakes all over the world is turning into a significant problem. The structures that make up hospitals are among the most significant buildings in a living society because, in the event that a potentially dangerous scenario emerges, they help to serve as a caring and healing unit for the human population. A hospital building is made up of three different components: the structural component, the non-structural component, and the functional component. Each of these components can have an effect, either directly or indirectly, on the management and operation of the hospital building. Each time a natural or non-natural cause causes devastation and disaster, the globe suffers. In such cases, hospital buildings are vital in term of treating victims and injured persons, and housing those who lost their homes. Therefore, hospital facilities should be planned and constructed with enough stiffness and strength to resist disasters and serve as shelters or housing units afterward. This study analyses a hospital in area of Surabaya which built using Indonesian standard provision SNI 1726-2012. Weak structural members of the hospital are identified. The analysis determined to study the behaviour of hospital building when subjected to seismic forces using ETABS using current provision SNI 1726-2019. The investigation determined that the effect of the lateral forces under P-delta effect on the hospital building. Two different conditions have been compared, e.g., existing model and alternative configuration using dual system method to determining the recommendation for current building to resist seismic forces under new regulation. As a result, existing structure of hospital building still meet the requirements, but to fill the condition in accordance with SNI 1726-2019, some modifications need to be improved.
Performance of High-Damping Rubber Bearings for Seismic Isolation – Case Study of Nayumi Sam Tower Malang Apartment Ibnu Pudji Raharjo; Yuyun Tajunnisa; Indra Komara; Geralda Nurry Arifa; Sungkono Sungkono; Dicky Imam Wahyudi
IPTEK The Journal of Engineering Vol 9, No 3 (2023)
Publisher : Lembaga Penelitian dan Pengabdian kepada Masyarakat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j23378557.v9i3.a16233

Abstract

The base-isolation system is a highly effective earthquake-resistance technique. Especially when the building is under soft soil, however, it is detrimental to the horizontal displacement control of the isolation layer and less effective in decreasing the seismic response of the superstructure. Rubber bearings with high damping can produce substantial hysteretic damping and exhibit a hardening effect at high-shear strains. The research investigates the Nayumi Sam Tower Malang apartment as a case study with 10 stories of reinforced concrete with a double system structure which is in a soft soil location. High-damping rubber bearings (HDRBs) is used as a parameter study to understand the alteration and give a recommendation. The seismic response of the building is evaluated, and the HRDB alternative systems is confirmed using ETABS. It is pointed out that the HRDBs system can reduce the impact of earthquakes by close to 25% with the smallest section of structural dimension. According to new regulation building in Indonesia, the precise values of test circumstances, such as compressive force, shear displacement, and frequency, are developed. The findings are thoroughly discussed, the applicability of HRDBs for seismic isolation of residential buildings is concluded. Building with HRDBs isolation implied to have lower base shear and inter-storey drift which improved the performance of the structure with less damage.