OPTIMALISASI DAYA LUARAN PANEL SURYA DENGAN SISTEM PENCARIAN INTENSITAS MATAHARI OPTIMAL DENGAN KONTROL FUZZY Muhammad Erpandi Dalimunthe
Jurnal Informatika dan Teknik Elektro Terapan Vol 12, No 3 (2024)
Publisher : Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/jitet.v12i3.5097

Abstract

To optimize the performance of sun tracking systems, adaptive and intelligent control techniques are required. One effective method for dealing with systems that have high uncertainty and non-linearity is fuzzy control. Fuzzy control has several advantages over conventional control methods, such as the ability to handle a variety of changing operating conditions and flexibility in application to various types of systems. By implementing fuzzy control, the sun tracking system can operate more efficiently, dynamically adjusting the tilt angle of the solar panels to obtain optimal sunlight intensity. In addition, the results of this research are expected to provide practical and applicable solutions for the development of renewable energy technology, especially in developing countries which have great potential for utilizing solar energy. Thus, this research has high urgency in the global and local context. . Optimizing the output power of solar panels through sun tracking systems with fuzzy control can be an important step towards a more sustainable, efficient and environmentally friendly energy system.
ANALISIS KINERJA MODIFIKASI ALAT PENGUKUR DAN PEMBATAS SATU PHASE DIPELANGGAN YANG MENYEBABKAN SUSUT NONTEKNIS DI PT.PLN ULP MEULABOH Muhammad Erpandi Dalimunthe
Jurnal Informatika dan Teknik Elektro Terapan Vol 12, No 3 (2024)
Publisher : Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/jitet.v12i3.5098

Abstract

Misuse of electricity by customers is the cause of non-technical losses. Non-technical losses result in losses to the state, where PLN as the party that distributes electricity unknowingly loses its main commodity without any reciprocity in the form of payment. The form of misuse that is most often found by customers is in the form of modifications to the Measuring and Limiting Equipment (APP). It is important to know the variations in One Phase APP Modifications made by customers because they can be used as a reference to increase the success of PLN's P2TL program to reduce non-technical losses. To find variations in these modifications, it is necessary to analyze each result of misuse by customers and also categorize them so that they are easy to classify. There are four types of abuse, each month the highest violations are Classes I and III, although the percentage decreases in the following months, down to 53% from the beginning of the month when it reached 80%, the losses received by PLN due to this violation are in the RP range. 291,166,223.00 Thus, analysis of this modification variation can improve the results of the P2TL Program in order to reduce losses to PLN.