Jurnal Purifikasi
Vol 5 No 3 (2004): Jurnal Purifikasi

EFFECT OF MAGNETIC FIELDS ON SELECTED PARAMETERS IN SEWAGE

S Johan (Unknown)



Article Info

Publish Date
04 May 2018

Abstract

Experimental design with a magnetic strength of 0.55 Tesla, a flow rate of 1.84 ml/s, 6 paired of non parallel magnets, with pH less than 7 showed that the concentrations of BOD, NH3-N, COD and SS were decreased up to three times using the settling test compared to typical treatment. The percentage of SS removal was 85.40 compared to 29.92 with-out magnet, so as BOD was 41.54 compared to 17.54, COD was 43.43 compared to 25.26 and NH3-N was 60.99 com-pared to 27.15 without magnet. This study concluded that magnetic technology had the potential to be used to further increase the efficiency of domestic sewage treatment by increasing the removal of suspended particles.

Copyrights © 2004






Journal Info

Abbrev

purifikasi

Publisher

Subject

Chemical Engineering, Chemistry & Bioengineering Environmental Science

Description

Jurnal Purifikasi was published since January 2000 by Division of Journal Purifikasi Department of Environmental Engineering-Faculty of Civil, Environment and Geo Engineering. Institut Teknologi Sepuluh Nopember, Surabaya in collaboration with the Association of Indonesian Sanitary and Environmental ...