Jurnal Ecolab
Vol 13, No 2 (2019): Ecolab

Monitoring of particulate matter 10 µm (PM10) in ambient air by means of Gent Sampler as an alternative to Beta Ray Automatic Analyzer for Air Pollution Mitigation

Rina Aprishanty (Environmental Management Center Ministry of Environment and Forestry (P3KLL-KLHK))
Rita Mukhtar (Environmental Management Center Ministry of Environment and Forestry (P3KLL-KLHK))
Ridwan Fauzi (Environmental Management Center Ministry of Environment and Forestry (P3KLL-KLHK))
Dwiana Lestiani (Center for Applied Nuclear Science and Technology (PSTNT), National Nuclear Energy Agency of Indonesia (BATAN))
Muhayatun Santoso (Center for Applied Nuclear Science and Technology (PSTNT), National Nuclear Energy Agency of Indonesia (BATAN))



Article Info

Publish Date
11 Nov 2019

Abstract

The monitoring of Particulate Matter 10 Mikron (PM10), as one of the critical parameters of air quality in Indonesia, requires equipment that can monitor the actual concentration for 24-hours continuously. Based on that, the anticipation of mitigation against conditions before an episode of pollution occurred can be carried out especially for areas with a history of forest and land fires. This study aimed to find out the correlation between PM10 using Gent sampler and PM10 using Beta Ray Analyzer. It is important to anticipate the current condition of local capacity in fulfilling monitoring data in one area lacking of sophisticated automatic monitoring instrument like Beta Ray Analyzer. The study was conducted at Pekanbaru station which belongs to the regional environmental office in Riau Province, during January 2013 to March 2014 covering 52 available data from manual sampling 24-hour weekly period using Gent Sampler. It was found that the PM10 concentration ranges from 12.7µg/NM3-148.6µg/NM3. The statistical analysis of this preliminary study pertaining the correlation coefficient of the two instruments reading is as high as 0.803. Pearson correlation analysis was employed in drawing the statistical inference. It is of interest to conclude that the gravimetric method of Gent Sampler can be used as an alternative method in monitoring particulate in ambient air.

Copyrights © 2019






Journal Info

Abbrev

JKLH

Publisher

Subject

Environmental Science

Description

Jurnal Ecolab adalah wadah yang merupakan sarana informasi dan publikasi berkaitan dengan kegiatan laboratorium lingkungan. Penerbitan Jurnal Ecolab untuk menampung berbagai informasi mengenai kajian ilmiah, hasil kegiatan pemantauan kualitas lingkungan dan kegiatan sejenisnya dari berbagai kalangan ...