Abstract

Coal power plant is designed based on a particular coal quality. Changes in coal quality will affect the quality of combustion and changes in combustion air. This study will describe the analysis of changes in coal quality on the ability of the force draft fan covers theoretical air, the percentage of air, capacity and force draft fan itself, and to analyze whether the capacity of force draft fan that existed at the time the design is adequate to the quality of coal that apply now .Berdasarkan calculation of theoretical air force draft fan air is 306 300 kg / s with the design power of 811 909 kW. Calculation of actual data shows the average air flow in the period from March to May was 307 610 kg of air / s. The capacity is still inadequate because of changes in the quality of the coal used is not too large.

Copyrights © 2016






Journal Info

Abbrev

powerplant

Publisher

Subject

Automotive Engineering Energy Industrial & Manufacturing Engineering Materials Science & Nanotechnology Mechanical Engineering

Description

The Scientific Journal of "Power Plant" is a collection of scientific works by lecturers, researchers, and practitioners in the field of Mechanical Engineering that have been published since September 2012. This journal is the result of scientific work, research in the fields of Energy, Materials ...