Indonesian Journal of Clinical Pathology and Medical Laboratory (IJCPML)
Vol 24, No 3 (2018)

COMPARISON OF HBA1C LEVEL USING TURBIDIMETRY INHIBITION IMMUNOASSAY, LATEX AGGLUTINATION INHIBITION METHOD AND HPLC METHOD

Salmon Sutandra (Department of Clinical Pathology, Faculty of Medicine, Hasanuddin University/Dr.Wahidin Sudirohusodo Hospital Makassar, Indonesia.)
Asvin Nurulita (Department of Clinical Pathology, Faculty of Medicine, Hasanuddin University/Dr.Wahidin Sudirohusodo Hospital Makassar, Indonesia.)
Mansyur Arif (Department of Clinical Pathology, Faculty of Medicine, Hasanuddin University/Dr.Wahidin Sudirohusodo Hospital Makassar, Indonesia.)



Article Info

Publish Date
01 Jul 2018

Abstract

According to the National Glycohemoglobin Standardization Program (NGSP) and The Diabetes Control and Complication Trial(DCCT) the standard method of measuring HbA1c is High-Performance Liquid Chromatography (HPLC), but HPLC requiresparticular instrument investments, trained staff, long and relatively expensive sample processing. This an instrument that hassimilar performance to HPLC but its operation process is relatively simple and not costly. The purpose of this study was to analysethe HbA1c level using Turbidimetry Inhibition Immunoassay (TII) method and the HPLC method; to analyse HbA1 level using LatexAgglutination Inhibition (LAI) method and HPLC method. This research was conducted with a cross-sectional design during theperiod of March-April 2017. The total sample consisted of 160 samples divided into two groups. For the first group, HbA1c levelusing TII method and HPLC method was measured. For the second group, HbA1c level was measured using LAI method and HPLCmethod.The data obtained were analyzed using the Paired T-test. There was a significant difference between HbA1c levels usingTII method and HPLC method {8.12(2.53)% vs. 8.49(2.63)%, p<0.001}. There was no significant differences between HbA1c levelsusing LAI method and HPLC method {7.52(1.95%) vs. 7.47(2.00)%, p>0.05}. This research concluded that there was a differencebetween the HbA1c levels using TII method and HPLC method, but no difference between HbA1c levels using LAI method and HPLC method.

Copyrights © 2018






Journal Info

Abbrev

patologi

Publisher

Subject

Biochemistry, Genetics & Molecular Biology Health Professions Medicine & Pharmacology Neuroscience

Description

Indonesian Journal of Clinical Pathology and Medical Laboratory (IJCPML) is a journal published by “Association of Clinical Pathologist” professional association. This journal displays articles in the Clinical Pathology and Medical Laboratory scope. Clinical Pathology has a couple of ...