ComEngApp : Computer Engineering and Applications Journal
Vol 8 No 3 (2019)

Accuracy Improvement of Incidence Level Detection Based on Electroencephalogram Using Fuzzy C-Means and Support Vector Machine

Marwan Ramdhany Edy (Institut Pertanian Bogor)
S. Wahjuni (Unknown)
S. N. Neyman (Unknown)



Article Info

Publish Date
24 Sep 2019

Abstract

Some jobs require that the concentration level be maintained for a long time during work time. Lack of sleep will in disruption of someone concentration level. To find out a human concentration level can be done by recording his/her brain waves. This research uses Electroencephalography (EEG) technology which functions to capture human brain waves. The focus of this study is to build a model of the detection system of a human concentration level. The research datasets are data from brain wave recording using Neurosky Mindwave Mobile which has extracted in 19 features. Data will then be labeled using cluster techniques namely Fuzzy C-Means to become data to be input into the classification process using Support Vector Machine (SVM). The classification results show an accuracy of 98.34%. That results show FCM can be used to automatically label EEG data properly.

Copyrights © 2019






Journal Info

Abbrev

comengapp

Publisher

Subject

Computer Science & IT Engineering

Description

ComEngApp-Journal (Collaboration between University of Sriwijaya, Kirklareli University and IAES) is an international forum for scientists and engineers involved in all aspects of computer engineering and technology to publish high quality and refereed papers. This Journal is an open access journal ...