PEMBUATAN MODUL PRAKTIKUM RELE PROTEKSI ARUS URUTAN NEGATIF DENGAN SEPAM 1000+

Hutomo, Tri (Unknown)
Facta, Mochammad (Unknown)
Karnoto, Karnoto (Unknown)



Article Info

Publish Date
06 Jan 2014

Abstract

Abstrak Adanya gangguan dalam sistem tenaga listrik merupakan masalah yang harus dihilangkan karena dapat menyebabkan ketidakseimbangan pada tegangan dan arus. Sistem tiga fasa yang tak seimbang pada arus dan tegangannya memiliki komponen urutan positif, negatif dan nol. Adanya komponen urutan negatif ini memiliki efek buruk terutama pada mesin listrik yaitu dapat mengakibatkan pemanasan yang mempengaruhi kekuatan isolasi sehingga mengurangi umur dari mesin listrik. Dalam upaya untuk mempelajari gangguan arus urutan negatif dan kinerja peralatan proteksi yang melindungi dari gangguan tersebut maka diperlukan sebuah prototipe sistem tenaga listrik yang dapat mensimulasikan gangguan tidak seimbang dan arus urutan negatif.  Berdasarkan hasil yang didapatkan pada simulasi program, maka nilai arus urutan negatif terbesar terjadi pada gangguan hubung singkat fasa ke fasa yakni sebesar 0.307 A dan nilai arus gangguan terkecil pada gangguan beban tak seimbang yakni 0.043 A. Gangguan satu fasa terbuka dan dua fasa terbuka memiliki nilai arus urutan negatif yang sama besar yaitu 0.045 A. Arus gangguan ini diukur pada sisi sekunder CT ideal dengan setting rasio 200:1. Kurva pemutusan rele SEPAM yang tepat untuk melindungi motor induksi tiga fasa 10 HP dari arus urutan negatif adalah tipe definite dengan waktu pemutusan 0.6 detik. Kata Kunci : proteksi , gangguan tak seimbang, arus urutan negatif  Abstract Faults in power systems are problems that must be cleared because several types of faults lead to unbalance of voltages and currents. Unbalanced three-phase system has positive, negative and zero sequence in the voltages and currents. Negative sequence has destructive effect especially to electric machine because it produces heat and reduces the quality of isolation and consequently it will shorten the lifetime of machine. In the effort to study the negative sequence currents fault and the performance of protection devices , a prototype of power system that can simulate unbalanced fault and negative sequence currents is required. Several results are obtained after program simulation. The highest negative sequence currents is obtained during phase to phase short circuit fault at  0.307 Ampere and the lowest one is unbalance load at 0.043 Ampere. One phase and two phase open faults have the same negative sequence currents magnitude at 0.045 Ampere. The fault currents are measured on secondary side of ideal CT with ratios setting 200:1. The definite curve of SEPAM relay is the most suitable tripping curve to protect 10 HP three-phase induction motor from the negative sequence currents with tripping time at 0.6s.  Keywords : protection, unbalance fault, negative sequence current 

Copyrights © 2013






Journal Info

Abbrev

transient

Publisher

Subject

Electrical & Electronics Engineering

Description

TRANSIENT: Jurnal Ilmiah Teknik Elektro (e-ISSN:2685-0206) diterbitkan oleh Departemen Teknik Elektro Universitas Diponegoro. Pertama kali terbit pada tahun 2012. TRANSIENT: Jurnal Ilmiah Teknik Elektro menerima artikel ilmiah dari pakar dan peneliti baik dari industri maupun akademisiTRANSIENT: ...