Inersia : Jurnal Teknik Sipil dan Arsitektur
Vol 10, No 2 (2014): Desember

EFEK VARIASI FAKTOR AIR SEMEN TERHADAP KUAT GESER PASANGAN DAN POLA KERUSAKKAN GESER PASANGAN BETON RINGAN AERASI MENGGUNAKAN THIN BED MORTAR

Candra Widiantoro Faqih Ma’arif (Unknown)



Article Info

Publish Date
12 Jul 2016

Abstract

This research aims to investigate the capacity of shear strength Autoclaved Aerated Concreteusing thin bed mortar as an adhesive with variations of water cement ratio and determine thecrack pattern. This research was conducted in the laboratory of building materials, Departmentof Civil Engineering and Planning, Faculty of Engineering, Yogyakarta State University. The testobject 20 x10x10cm in dimension. The adhesive material was used thin bed mortar with varietyof water cement ratio 0.15; 0.20; and 0.25 respectively. The test results showed that the shearstrength average with f.a.s 0.15 ; 0.20 ; and 0.25 were 0,243 MPa; 0.269 MPa ; and 0,270 MPa;The crack pattern is combination failure.

Copyrights © 2014






Journal Info

Abbrev

inersia

Publisher

Subject

Civil Engineering, Building, Construction & Architecture

Description

INERSIA is stand for INformasi dan Ekspose hasil Riset Teknik SIpil dan Arsitektur. This scientific journal is managed by the Department of Civil Engineering and Planning Education, Faculty of Engineering, Yogyakarta State University, in cooperation with the Persatuan Insinyur Indonesia (PII). It ...