ANALISIS DAN PENGUKURAN PARAMETER REAKTOR KARTINI UNTUK PENERAPAN METODE K0-NAA

Sri Murniasih (Pusat Sains dan Teknologi Akselerator – BATAN)
Roto Roto (Jurusan Kimia, Fakultas Matematika dan Ilmu Pengetahuan Alam – UGM)
Agus Taftazani (Pusat Sains dan Teknologi Akselerator – BATAN)
Th. Rina M. (Pusat Sains dan Teknologi Akselerator – BATAN)
Sutisna Sutisna (Pusat Sains dan Teknologi Akselerator – BATAN)



Article Info

Publish Date
28 Mar 2015

Abstract

Metode k0-NAA merupakan metode analisis yang banyak digunakan dengan berbagai keunggulan. Dalam penerapan metode k0-NAA diperlukan nilai parameter reaktor (f dan α), maka tujuan penelitian ini adalah akan dilakukan pengukuran nilai parameter f dan α di fasilitas Lazy Susan reaktor Kartini. Metode yang digunakan meliputi metode Cd-ratio dan triple bare. Telah diukur nilai parameter tersebut pada tiga lubang iradiasi di fasilitas Lazy Susan. Diperoleh perbedaan hasil pengukuran nilai parameter yang signifikan pada setiap lubang iradiasi, nilai ƒ berkisar 13,713 - 22,128 dan α berkisar -0,060 – 0,068. Hasil pengukuran f dan α dengan metode Cd-ratio, memberikan nilai yang lebih stabil dibandingkan metode triple bare. Nilai f dan α yang diperoleh dapat dijadikan basis data pada penerapan metode k0-NAA untuk analisis sampel di laboratorium AAN – PSTA.Kata kunci: parameter reaktor, reaktor Kartini, k0-NAA, fluks neutron  The k0-NAA method is an analysis method that widely used by many of the advantages. In the application of k0-NAA method needed valuea of reactor parameters (f and α), then the purpose of the research would be conducted meaasurement parameter values f and α in the Lazy Susan Kartini reactor facilities. The methods used include Cd-ratio and triple bare methods. The parameter value has been measured in three channels in the irradiation facilities Lazy Susan. Differences of measurement results obtained parameter values are significant in each channel irradiation, the value of ƒ ranged from 13.713 to 22.128 and the value of α ranged from -0.060 – 0.068. The results of measurements for the f and α with the Cd-ratio method, providing more stable value than the triple bare method. The value of f and α obtained can be used a database for the application of k0-NAA method for sample analysis in the laboratory NAA – CAST. Keywords: reactor parameter, Kartini reactor, k0-NAA, neutron flux

Copyrights © 2014






Journal Info

Abbrev

tridam

Publisher

Subject

Energy Materials Science & Nanotechnology

Description

Jurnal Teknologi Reaktor Nuklir "TRI DASA MEGA" adalah forum penulisan ilmiah tentang hasil kajian, penelitian dan pengembangan tentang reaktor nuklir pada umumnya, yang meliputi fisika reaktor, termohidrolika reaktor, teknologi reaktor, instrumentasi reaktor, operasi reaktor dan lain-lain yang ...