Abstract

A field sound transmission loss measurement to obtain the field sound transmission class (FSTC) from partition between spaces on 27th floor Tower "A" in Jakarta was conducted in April 1st, 2017. The measurement graph showed that, although the trend indicates an increase, but the graph shape like saw tooth shape indicates sound leakages. This measurement yielded 41 dB for the FSTC rating, which is considered far from the previous expectation, about 50 dB. After further analysis, the most dominant sound leakage was contributed by flanking noise via ducting works.Keywords: field sound transmission loss measurement, field sound transmission class, FSTC, sound leakage.

Copyrights © 2017






Journal Info

Abbrev

ji

Publisher

Subject

Agriculture, Biological Sciences & Forestry Chemistry Electrical & Electronics Engineering Engineering Materials Science & Nanotechnology

Description

The scientific areas covered by Instrumentasi are those backboned by scientific measurements and thus range from instrument engineering, metrology, testing, and control. All papers submitted are refereed by bona fide reviewers from leading research institutions as well as universities prior to ...