Info-Teknik
Vol 6, No 2 (2005): INFOTEKNIK VOL. 6 NO. 2 2005

KOEFISIEN PERPINDAHAN MASSA DALAM EKSTRAKTOR TANGKI BERPENGADUK

Muthia Elma (PS T. Kimia FT Unlam)



Article Info

Publish Date
16 Sep 2016

Abstract

liquid-liquid extraction in a mixer tank was widely used to reach a certain mass transfer rate. Mass transfer rate in a mixer tank extractor is declared as mass transfer coefficient. This research intends to learn how mass transfer coefficient does in a mixer tank extractor and variables that influence mass transfer coefficient.  Determination of mass transfer coefficient in a mixer tank extractor is a function of mixer rate and characteristic of physical system.  This system study about water – acetic acid – methyl acetic between CMC as a phase concentration in a solvent.  The influences of  variable to mass transfer coefficient in a equation of non-dimention group is; Sh=7396.05 Re0.82 Sch -0.35.For whirlmixer, rate is between 1 to 4 circle/s and solvent viscosity is between 1 to 6.18 cP, and for whirlReynold, rate is between 2500 to 1000 and whirlSchmidt is between 689.655 to 4262.07.

Copyrights © 2005






Journal Info

Abbrev

infoteknik

Publisher

Subject

Engineering

Description

Jurnal Info – Teknik menerbitkan artikel – artikel karya orisinil dan signifikan pada Bidang Rekayasa ...