THE EFFECTIVENESS OF UVAERATOR IN REDUCING AIR GERMS AND DUST LEVELS

Tri Cahyono (Poltekkes Kemenkes Semarang)
Teguh Widiyanto (Poltekkes Kemenkes Semarang)



Article Info

Publish Date
31 Dec 2020

Abstract

Background, school education facilities, including higher education as a place and public facilities for formal education facilities in this country, should be a comfortable place to study. Besides functioning as a place of learning, schools can also be a threat of disease transmission . measurement number of bacteria in the air-conditioned classrooms Wulan R22 (2016) 12.167 CFU / m3 , Nur Latifah (2018) an average of 217.92 colony / hr / ft2 , hadita (2018) 331.6 colonies / hr / ft2 . Research question is how is the effectiveness of UVAerator in reducing the number of air germs and dust levels in the lecture hall R22 building Campus 7 Poltekkes Kemenkes Semarang ? Research objectives is to find the effectiveness of UVAerator in reducing the number of air germs and dust levels in the lecture hall. Research method included a quasi-experimental design with a non-equivalent control group pre test - post test. Data collection by measuring, observational, interview. The variables were temperature, humidity, lighting, air germ count, dust content. Analysis using pairet-t test comparisons and unpaired t test data. Result, the average number of bacteria with no air space UVAerator in the morning is ( 668,00 g / m3 ) and in the afternoon is ( 680.10 g / m3 ) the difference was not significant (p = 0.873), whereas the existing space UVAerator in the morning ( 876.50 g / m3 ) and in the afternoon ( 655.50 g / m3 ) shows significant difference (p = 0.001). The number of room air germs that do not exist and have UVAerator is significantly different (p = 0.002), the number of room air germs that are not there and without any UVAerator is not significant (p = 0.763), while the change in the number of room air germs that does not exist and exist UVAerator has a significant difference (p = 0.015). On average PM10 space dust that has no UVAerator in the morning ( 12.38 ug / m3 ) and in the afternoon ( 17.38 ug / m3 ) shows significant difference (p = 0.008), whereas the existing space UVAerator in the morning ( 11.63 g / m3 ) and day ( 14.50 µg / m3 ) shows that the difference is not significant (p = 0.127). PM10 dust in the room that does not exist and there is no UVAerator ported, the difference is not significant (p = 0.821), the PM10 dust in the room noon and there is UVAerator, the difference shows that it is not significant (p = 0.432), while the change in room PM10 without dust and there is a difference in UVAerator significant (p = 0.004). In conclusion, the effectiveness of reducing the number of air germs without UVAerator on average (4.56%), with UVAerator (-24.52%), the difference was not significant (p = 0.057). The effectiveness of reducing PM10 without UVAerator, mean (60.50%), with UVAerator (38.30%), the difference was not significant (p = 0.369). Suggestion, , It is necessary to control the sound intensity caused by UVAerator by adding aeration bubble breakers. The pump suction power is enlarged to accelerate the circulation of room air.

Copyrights © 2020






Journal Info

Abbrev

keslingmas

Publisher

Subject

Environmental Science Health Professions Public Health

Description

Buletin Keslingmas mencakup bidang penelitian bidang sanitasi /penyehatan air, penyehatan udara, penyehatan makanan, penyehatan tanah/ pengelolaan sampah, pengendalian vektor, penyehatan sarana fasilitas, Kesehatan dan Keselamat Kerja, Epidemiologi Kesehatan Lingkungan. ...