GAMMA RADIATION ANALYSIS ON IN VIVO/ IN VITRO TESTING FACILITY BORON NEUTRON CAPTURE THERAPY

Gabriel Simanjuntak (STTN-BATAN)



Article Info

Publish Date
31 Oct 2020

Abstract

BNCT is the latest method in nuclear technology that combines chemotherapy and radiotherapy. Therapy that uses ionizing radiation must pay attention to the safety of patients, radiation workers and the environment. Therefore, shielding is needed for radiation protection, especially gamma radiation. A refining for the shielding and the testing had been done to know the limitation for the use of testing facility in vivo / in vitro that meets the NPD/Dose Constraint limitation from PSTA BATAN with parameter shielding radiation outcome, shielding geometry, and energy value Kartini Reactor. The highest measurement result reaches 4.8 mSv/j with 100kW energy. By considering the measurement result with the NPD/Dose Constraint limitation from PSTA BATAN for Kartini Reactor operation, the activity of testing facility in vivo/in vitro can be done 46 times in a year. Keywords : BNCT, Shielding, Gamma Radiation.

Copyrights © 2020






Journal Info

Abbrev

ijpna

Publisher

Subject

Environmental Science Physics

Description

Indonesian Journal of Physics and Nuclear Applications is an international research journal, which publishes top level work from all areas of physics and nuclear applications including health, industry, energy, agriculture, etc. It is inisiated by results on research and development of Indonesian ...