JURNAL INTEGRASI
Vol 12 No 2 (2020): Jurnal Integrasi - Oktober 2020

PENGUKURAN PARTIKEL DI CLEANROOM TFME POLITEKNIK NEGERI BATAM MENGGUNAKAN STANDAR ISO 14644-1

Aditya Gautama (Politeknik Negeri Batam)
Budiana Budiana (Politeknik Negeri Batam)



Article Info

Publish Date
31 Oct 2020

Abstract

Electronics Tecnology is currently developing very rapidly. Computational capabilities that continue to increase are accompanied by a decrease in the size of the electronic components used on a chip or IC (Integrated Circuit). The size of the components that have reached nanometers makes the components very sensitive to impurities in the form of particles. A special fabrication place in the form of a cleanroom is needed so that the number of impurity particles can be controlled and the damage caused by impurity particles on the product can be reduced. One of the standards used to classify a cleanroom and measure the particles in it is ISO 14644-1. In this study, particle measurements were carried out in accordance with ISO 14644-1 standards to measure the number of particles in the TFME cleanroom. The measurement results classify the cleanroom in TFME into ISO Class 7. This is consistent with the initial TFME cleanroom design, meaning that the particle filtration system is still in a good condition.

Copyrights © 2020






Journal Info

Abbrev

JI

Publisher

Subject

Other

Description

Terbit dua kali setahun pada bulan April dan Oktober: mulai Volume 10, Nomor 1, April 2018. Berisi tulisan yang diangkat dari hasil penelitian di bidang Teknologi Terapan. e-ISSN: ...