Eksakta : Berkala Ilmiah Bidang MIPA
Vol. 21 No. 2 (2020): Eksakta : Berkala Ilmiah Bidang MIPA (E-ISSN : 2549-7464)

Algorithm of Time and Frequency Remote Calibration System of SNSU-BSN

A. Mohamad Boynawan (Center for Research and Human Resources Development, National Standardization Agency of Indonesia and National Measurement Standards Laboratory, National Standardization Agency of Indonesia)
Ratnaningsih Ratnaningsih (Center for Research and Human Resources Development, National Standardization Agency of Indonesia and National Measurement Standards Laboratory, National Standardization Agency of Indonesia)
Windi Kurnia P (Center for Research and Human Resources Development, National Standardization Agency of Indonesia and National Measurement Standards Laboratory, National Standardization Agency of Indonesia)
Yulita Ika P (Center for Research and Human Resources Development, National Standardization Agency of Indonesia and National Measurement Standards Laboratory, National Standardization Agency of Indonesia)
Asep Hapiddin (Center for Research and Human Resources Development, National Standardization Agency of Indonesia and National Measurement Standards Laboratory, National Standardization Agency of Indonesia)
Muhammad Azzumar (Center for Research and Human Resources Development, National Standardization Agency of Indonesia and National Measurement Standards Laboratory, National Standardization Agency of Indonesia)



Article Info

Publish Date
30 Sep 2020

Abstract

National Measurement Standards-National Standardization Agency of Indonesia (SNSU-BSN) as the National Metrology Institute of Indonesia has provided time and frequency calibration services for customers. Time and frequency equipment should be calibrated to traceable to the SI units. The calibration process can be carried out in a calibration laboratory. However, some measuring devices cannot be sent to the calibration laboratory. One of the devices that cannot be sent to the calibration laboratory is Cesium atomic clock. It must be calibrated to get the time difference with the local coordinated universal time (UTC), namely UTC(IDN). Therefore, to calibrate the Cesium atomic clock, a remote calibration method is needed. The remote system is also intended to conduct the calibration more effectively and efficiently. This method requires two Global Positioning System (GPS) receiver devices placed on the client-side and a calibration laboratory. For this reason, an algorithm for remote calibration has been developed. The algorithm has been tested to calibrate Cesium-3 of SNSU-BSN against UTC(IDN). The time difference between Cesium-3 and UTC(IDN) was 5.8 microseconds by using the algorithm. Based on the algorithm that has been built, it was concluded that the algorithm can be used to perform remote calibration for the related customer.

Copyrights © 2020






Journal Info

Abbrev

eksakta

Publisher

Subject

Agriculture, Biological Sciences & Forestry Astronomy Biochemistry, Genetics & Molecular Biology Chemical Engineering, Chemistry & Bioengineering Chemistry Civil Engineering, Building, Construction & Architecture Computer Science & IT Energy Engineering Environmental Science Materials Science & Nanotechnology Mathematics Mechanical Engineering

Description

Eksakta : Berkala Ilmiah Bidang MIPA (E-ISSN : 2549-7464) is an open access journal and peer-reviewed that publishes either original article or reviews. The journal is dedicated towards dissemination of knowledge related to the advancement in scientific research. The prestigious interdisciplinary ...