Journal of Geoscience, Engineering, Environment, and Technology
Vol. 5 No. 4 (2020): JGEET Vol 05 No 04: December 2020

Investigation of Groundwater Potential using Electrical Resistivity Method and Hydraulic Parameters in Lam Apeng, Aceh Besar, Indonesia.

Dian Darisma (Department of Geophysical Engineering, Faculty of Engineering, Universitas Syiah Kuala, Aceh, Indonesia.)
Ferdy Fernanda (Department of Geophysical Engineering, Faculty of Engineering, Universitas Syiah Kuala, Aceh, Indonesia.)
Muhammad Syukri (Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Syiah Kuala, Aceh, Indonesia.)



Article Info

Publish Date
15 Dec 2020

Abstract

Lam Apeng is a village with a majority of people living as farmers, which causes the need of water for agriculture is increasing. The water demand in this area continues to increase as the population increases, for various purposes. The objective of this study is to determine the distribution of the groundwater layer using the electrical resistivity method and to determine groundwater potential using hydraulic parameters. This research is conducted using 2 measurement line with a length of each line is 112 meters and distances of each electrode is 2 meters. The data invert using Res2Dinv software to obtain 2D subsurface lithology subsurface. At line 1, the aquifer (sand) layer is located in the second layer with a rock resistivity value of 12 Ωm - 18.6 Ωm at a depth of 8 m - 18 m. At line 2, the aquifer (sand) layer is also located in the second layer with a resistivity value of 4.6 Ωm - 18 Ωm at a depth of 5 m – 12 m. Based on the interpretation of the two measurement lines, it can be concluded that the type of aquifer in the research site is a semi unconfined aquifer. In this study, hydraulic parameters (hydraulic conductivity, longitudinal conductance, transverse resistance, and transmissivity) was calculated based on the resistivity value and the thickness of the aquifer layer. The average resistivity of the aquifer layer used is 15.3 Ωm and 11.3 Ωm, respectively for line 1 and line 2, indicating that the aquifer was moderately corrosive. Longitudinal conductance values are 0.65 Ω-1 and 0.62 Ω-1 which indicated moderate protective capacity. The transmissivity values are 6.78 m2/dayand 4.77 m2/day, which indicates that the designation in this area is low and the groundwater potential is local or only for personal consumption.

Copyrights © 2020






Journal Info

Abbrev

JGEET

Publisher

Subject

Earth & Planetary Sciences Engineering Environmental Science Physics

Description

JGEET (Journal of Geoscience, Engineering, Environment and Technology) published the original research papers or reviews about the earth and planetary science, engineering, environment, and development of Technology related to geoscience. The objective of this journal is to disseminate the results ...