Atom Indonesia Journal
Vol 48, No 1 (2022): April 2022

Correlations Between Body Weight and Size-Specific Dose Estimate on Thoracic Computed Tomography Examination

A. L. Wati (Departemen of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof.Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia)
C. Anam (Departemen of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof.Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia)
A. Nitasari (Departemen of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof.Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia)
S Syarifudin (Departement of Radiology, Dr Kariadi Hospital, Jl Dr Sutomo No 19 Semarang, Central Java, Indonesia)
G. Dougherty (Department of Applied Physics and Medical Imaging, California State University Channel Islands, Camarillo, CA, USA)



Article Info

Publish Date
06 Apr 2022

Abstract

The dose received by a patient on CT examination is expressed in size-specific dose estimates (SSDE) which is a function of the patient diameter, x-ray attenuation, and scanner output (volume computed tomography dose index, CTDIvol). Patient diameter and x-ray attenuation are represented as water equivalent diameter (Dw). We conducted the research to analyze the relationships between body weight and Dw, CTDIvol, and size-specific dose estimates (SSDE) in contrast-enhanced thorax examinations. We used images from 100 patients (50 women and 50 men patients) whose weight range from 2.8 kg to 80 kg. The values of Dw, CTDIvol, and SSDE were automatically calculated from axial CT images using the IndoseCT software. Statistical analysis showed that the patient's body weight correlates linearly with the Dw. The linearity coefficient (R2) values for body weight and Dw is 0.43 (women) and 0.55 (men). However, weight was independent of the patient dose in terms of CTDIvol and SSDE. This was because the CT system used tube current modulation (TCM), which automatically adapted the tube current to patient size, resulting in a relatively constant dose regardless of the patient size (Dw).

Copyrights © 2022






Journal Info

Abbrev

aij

Publisher

Subject

Materials Science & Nanotechnology

Description

Exist for publishing the results of research and development in nuclear science and technology Starting for 2010 Atom Indonesia published three times a year in April, August, and December The scope of this journal covers experimental and analytical research in all areas of nuclear science and ...