BackgroundEndoscopic ultrasound guided fine needle aspiration (EUS-FNA) of the pancreas and biliary brushes is a minimally invasive method ofcytology sampling. The purpose of this study was to determine the sensitivity, specificity, and accuracy of examination of biliary brushcytology and EUS-FNA pancreas based on the System of standardized terminology and nomenclature for pancreatobilliary cytology(STNPC) as well as cytology characteristics of pancreatic malignancy.MethodsA search of the biliary brush preparation and EUS-FNA pancreatic in 2017-2020 was carried out in the Archives section of the Department ofAnatomical Pathology FKUI / RSCM. 506 cases of biliary brush cytology and EUS-FNA pancreatic, conducted a search of histopathologicalpreparations and re-categorized based on STNPC.ResultsCytological cases of biliary brushing and pancreatic EUS-FNA paired with histopathology in 2017-2020 151 cases, 85 cases of biliarybrushing and 66 cases of pancreatic EUS-FNA, were re-categorized based on STNPC with results of biliary brushing 27 non-diagnosticcases, 24 atypical cases, 7 suspicious for malignancy (SFM) cases and 17 malignant cases. Meanwhile, for pancreatic EUS-FNA cytology16 non-diagnostic cases, 2 negative cases, 16 atypical cases, 3 other neoplasms, 4 SFM cases and 25 malignant cases. Twenty sevencases of false negative biliary brushes on non-diagnostic and atypical preparations and 4 cases of false negative on pancreatic EUS-FNA onnon-diagnostic and atypical preparations. Biliary brushing diagnostic test results: sensitivity 82.35%, specificity 100%, positive predictivevalue (PPV) 100%, negative predictive value (NPV) 84.21% and accuracy 90.9%. In pancreatic EUS-FNA: sensitivity 84.21%, specificity100%, PPV 100%, NPV 986.67% and accuracy 92.86%.ConclusionCytological diagnosis of biliary brushing and pancreatic EUS-FNA has good specificity, sensitivity and accuracy, but definitive diagnosisrequires histopathological examination

Copyrights © 2022






Journal Info

Abbrev

patologi

Publisher

Subject

Health Professions Public Health

Description

Majalah Patologi Indonesia (MPI) digunakan sebagai wahana publikasi hasil penelitian, tinjauan pustaka, laporan kasus dan ulasan berbagai aspek di bidang patologi manusia. Tujuannya ialah menghadirkan forum bagi permakluman dan pemahaman aneka proses patologik serta evaluasi berbagai penerapan cara ...