Atom Indonesia Journal
Vol 38, No 1 (2012): April 2012

Preparation of Sulfonated Poly (ethylene-co-tetrafluoroethylene-graft-styrene) Based Polymer Electrolyte Membranes for Fuel Cell by using Gamma Irradiation Technique

A. Suliwarno (Center for the Application of Isotopes and Radiation Technology, National Nuclear Energy Agency Jl. Lebak Bulus Raya No. 49, Jakarta 12440, Indonesia)



Article Info

Publish Date
26 Sep 2012

Abstract

Poly (ethylene-co-tetrafluoroethylene-graft-styrene-sulfonate) was successfully prepared by irradiation grafting of a styrene monomer into ethylenetetrafluoro-ethylene (ETFE) films and followed by sulfonation of the graft chains. Five film sheets of ETFE which having a size of 3 cm x 8 cm, thickness of 25 µm were packed in vacuum using a Y type tube filled with argon gas. The samples were irradiated using γ-rays with a dose of 15 kGy at 15 kGy/h. The iradiated samples were grafted by using styrene monomer at 60o C for 1, 3, 5, 7 and 9 h, respectively. The grafted samples (ETFE-g-St) were washed with xylene to remove homopolymer of polystyrene, and then its degree of grafting (DG) was determined. Sulfonation was carried out by using 0.2 M chlorosulfonic acid in dichloroethane solution at a water bath of 60oC for 6 h. Sulfonated samples (ETFE-g-St-SO3H) were washed with water to neutralize its acidity, and dried in a vacuum drier at 40oC for 15 h. The dried sample was weighed as sulfonated sample in order to determine the degree of sulfonation (%DS). Membrane properties of EFTE-g-St-SO3H sample such as ion exchange capacity (IEC), proton conductivity in cross direction (σ1), and in-plane direction (σ11) were determined by using a HIOKI-3522 LCR HI tester. Durability test of samples were conducted in hot water and 3% H2O2 respectively.. The proton conductivity measurement and durability of the membrane were compared to Nafion 112® as standard. The experimental results showed that the degree of grafting was increased with time of reaction for copolymerization, while %DS gave excellent results with an average of 92.7%. The IEC value was more affected by the %DG as compared to that of %DS effect. The average of σl value of the sample was 0.055 S/cm, compared to σ1 of Nafion112® that was 0.066 S/cm. The average of σ11 of the sample was 0.18 S/cm, while the σ11 of Nafion 112® was = 0.36 S/cm. The sample of SA004 with 53.49% DG was more stable than both the SA001 (21.48%DG) and SA003 (41.52% DG) in durability’s test of the samples against hot water (334 h resistance). On the peroxides test, all of samples were degraded at 114 h. Received: 20 November 2011; Revised: 28 March 2012; Accepted: 30 April 2012

Copyrights © 2012






Journal Info

Abbrev

aij

Publisher

Subject

Materials Science & Nanotechnology

Description

Exist for publishing the results of research and development in nuclear science and technology Starting for 2010 Atom Indonesia published three times a year in April, August, and December The scope of this journal covers experimental and analytical research in all areas of nuclear science and ...