Atom Indonesia Journal
Vol 38, No 3 (2012): December 2012

Labeling of the Recombinant Streptokinase Using Iodine-131 as a New Thrombolytic Agent

I. Daruwati (Center for Nuclear Technology of Material and Radiometry, National Nuclear Energy Agency Jl.Tamansari 71 Bandung 40132, Indonesia)
A. Hanafiah (Center for Nuclear Technology of Material and Radiometry, National Nuclear Energy Agency Jl.Tamansari 71 Bandung 40132, Indonesia)
D.S. Retnoningrum (School of Pharmacy, Bandung Institute of Technology Jl.Ganesa 10 Bandung 40132, Indonesia)
H. Rachmawati (School of Pharmacy, Bandung Institute of Technology Jl.Ganesa 10 Bandung 40132, Indonesia)



Article Info

Publish Date
12 Feb 2013

Abstract

Stroke and acute myocardial infarction is a disease with the highest mortality in the world. WHO has estimated in 2008, 30% of deaths from heart disease and more than 80% of this cases have been occurred in developing countries. Streptokinase (SK) as an effective thrombolytic agent has been used as a drug of choice for about forty years ago. SK is plasminogen (PG) activator that converts plasminogen to active protease, called plasmin (PN) which degrades fibrin to soluble products. Recombinant streptokinase (SKA) from genetic engineering has been developed at School of Pharmacy ITB to reduce or eliminate immunogenicity of SK. However, scientific disclosures relating to dynamic and its kinetic studies in the body have still to be proven. One method that can explain this phenomenon is the pharmacological studies using radionuclide labeled compounds. Radioiodine labeled compound is used extensively and most suitable for biological studies. This paper describes the preparation of 131I-SKA and its characterization. The labeling conditions of SKA, such as chloramine-T as an oxidizing agent, amount of SKA, incubation time, and size of resin to purify the labeling yield have been observed. The result showed that the optimum condition of labeling (35.11%) was obtained using 10 µg of chloramine-T and 60 seconds of incubation time. The highest radiochemical purity (97.46 ± 1.14%) has also been obtained by passing through the resin chromatography column using 100 mg Dowex 1x8, size 50-100 mesh. The characterization of 131I-SKA with SDS PAGE method and autoradiography showed the similar performance with unlabeled-SKA.Received: 04 December 2012; Revised: 20 December 2012; Accepted: 21 December 2012

Copyrights © 2012






Journal Info

Abbrev

aij

Publisher

Subject

Materials Science & Nanotechnology

Description

Exist for publishing the results of research and development in nuclear science and technology Starting for 2010 Atom Indonesia published three times a year in April, August, and December The scope of this journal covers experimental and analytical research in all areas of nuclear science and ...