Indonesian Journal of Cardiology
Vol. 38, No. 1 Januari-Maret 2017

Laporan Dua Kasus Sindrom Twiddler pada Pasien dengan Pemasangan Implanted Cardioverter-Defibrillator dan Permanent Pacemaker

Pipiet Wulandari (Department of Cardiology and Vascular Medicine, Faculty of Medicine Universitas Sebelas Maret)
Sunu B Raharjo (Department of Cardiology and Vascular Medicine, Faculty of Medicine Universitas Indonesia-Harapan Kita National Cardiovascular Center)
Dicky A Hanafy (Department of Cardiology and Vascular Medicine, Faculty of Medicine Universitas Indonesia-Harapan Kita National Cardiovascular Center)
Lina Haryati (Department of Cardiology and Vascular Medicine, Faculty of Medicine Universitas Brawijaya)
Yoga Yuniadi (Department of Cardiology and Vascular Medicine, Faculty of Medicine Universitas Indonesia-Harapan Kita National Cardiovascular Center)



Article Info

Publish Date
30 Oct 2017

Abstract

Background: Twiddler syndrome is an infrequent but potentially dangerous complication of device therapy for dysrhythmias. This syndrome results from manipulation of implanted pulse generator by the patient, leading to traction and subsequent lead dislodgement. It can also occur spontaneously. It has been increasingly reported with pacemaker or implantable cardioverter-defibrillators (ICDs). In this reports, we describe two patients with Twiddler syndrome with substantial retraction of their lead who denied any manipulation of their device.Case Illustration: The first patient was a 56 year-old man with single-chamber ICD due to dilated cardiomyopathy (DCM) with congestive heart failure and severe systolic left ventricular dysfunction (ejection fraction 18%). The dislodged lead causing rhythmical twitching of left pectoral muscles and abdominal pulsations. The second patient was a 69 year-old man with dual-chamber pacemaker due to total atrioventricular block with normal systolic left ventricular function (ejection fraction 70%). It manifested as dyspnea on effort, and he also underwent pacemaker implantation. They underwent primary devices implantation at April 2016 and reposition of generators and its leads in December 2016. The first and second patients denied of manipulating the generator of ICD or pacemaker and rotated their left arm and right arm, respectively, after implantation.Summary: Other unconscious arm abduction during sleep or increased muscular activity of the shoulder and arm might have led to repetitive motions within the pocket and dislodge the device. Adequate individualized patient and family education and regular evaluation every 6 month of the leads position with fluoroscopy or chest X-ray is advisable.

Copyrights © 2017






Journal Info

Abbrev

ijc

Publisher

Subject

Health Professions Medicine & Pharmacology

Description

Indonesian Journal of Cardiology (IJC) is a peer-reviewed and open-access journal established by Indonesian Heart Association (IHA)/Perhimpunan Dokter Spesialis Kardiovaskular Indonesia (PERKI) [www.inaheart.org] on the year 1979. This journal is published to meet the needs of physicians and other ...