Separation condenser is one of the types of condenser equipped with gas and liquid separator. The previous research using separation condenser showed low output temperature of 1.3 K than baseline condenser. This study is to observe the effect of separation and baseline condenser to the performance of the refrigerator with a double evaporator and using LPG and R134A as a refrigerant. This research using a parallel circuit for separation condenser and baseline. The result showed that using R134A gives 0.16% higher value of COP. Meanwhile, using double evaporator with R134A as a refrigerant gives 69.5 % higher value of COP than single evaporator.
                        
                        
                        
                        
                            
                                Copyrights © 2022