ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika
Vol 10, No 3: Published July 2022

Rancang Bangun Instalasi Uji Akurasi Meter Air untuk Studi Pengaruh Tekanan Air

FIRMANSYAH, DUDI ADI (Unknown)
AHMAD, SAYYID AL HABBIB (Unknown)
PRIYATNA, ENDANG (Unknown)
FIRMANSYAH, VERA (Unknown)
SUPRIJANTO, SUPRIJANTO (Unknown)



Article Info

Publish Date
19 Jul 2022

Abstract

ABSTRAKPada distribusi air bersih kepada konsumen, tekanan permulaan biasanya dibuat lebih tinggi dan sering berubah pada saat aliran. Kondisi ini dapat mempengaruhi akurasi meter air, meskipun alat ini didesain untuk dapat beroperasi pada rentang tekanan lebar. Oleh karenanya, pada penelitian ini, prototipe instalasi uji dibuat untuk mempelajari pengaruh tekanan air pada akurasi meter air secara bersamaan. Prototipe ini terdiri dari dua pompa yang mampu menghasilkan tekanan air tinggi, sensor tekanan posisi hulu dan hilir, pengatur aliran, sensor aliran, meter air, sensor suhu, dan sebuah sistem akuisisi data nirkabel dengan perhitungan otomatis. Hasil kalibrasi menunjukan bahwa semua sensor memiliki rata-rata akurasi 99,4% dan presisi 99,7%. Hasil pengujian akurasi meter air pada kenaikan tekanan dari 0,5 bar ke 4,5 bar menunjukan nilai kesalahan meter air yang semakin meningkat dari 5,1% menjadi 7,2%, sehingga pada studi ini dapat dilakukan pengujian akurasi meter air pada tekanan air yang lebih tinggi dibandingkan dengan penelitian sebelumnya.Kata kunci: tekanan, akurasi, instalasi uji, perhitungan otomatis ABSTRACTIn the water distribution, the starting pressure is usually made higher and frequently changes during the flow. This condition can affect the accuracy of water meter, though it was designed to be operated at a wider pressure range. Therefore, a prototype of testing installation is assembled to study the effect of the water pressure to the water meter accuracy simultaneously. It consists of two pumps which able to generate high water pressure, pressure sensor (upstream and downstream), flow regulator, flowmeter sensor, water meter, temperature sensor, and wireless data acquisition system with automatic calculation. Calibration results show that all sensors have average accuracy of 99.4% and precision of 99.7%. Water meter accuracy testing results at the increasing pressure from 0,5 bar to 4,5 bar show that water meter error values increase from 5,1% to 7,2%, so this study can perform accuracy test at a higher water pressure as compared to the previous research.Keywords: pressure, accuracy, testing installation, automatic calculation

Copyrights © 2022






Journal Info

Abbrev

elkomika

Publisher

Subject

Electrical & Electronics Engineering Engineering

Description

Jurnal ELKOMIKA diterbitkan 3 (tiga) kali dalam satu tahun pada bulan Januari, Mei dan September. Jurnal ini berisi tulisan yang diangkat dari hasil penelitian dan kajian analisis di bidang ilmu pengetahuan dan teknologi, khususnya pada Teknik Energi Elektrik, Teknik Telekomunikasi, dan Teknik ...