Jurnal Ilmiah Sains
Volume 18 Nomor 1, April 2018

PENENTUAN KADMIUM MENGGUNAKAN METODE PAPER ANALYTICAL DEVICE (PAD) DENGAN TEKNIK PENCITRAAN DIGITAL DALAM SAMPEL MAKANAN

Zuri Rismiarti (Prodi Diploma Analisis Farmasi dan Makanan (Anafarma), Jurusan Gizi. Politeknik Kesehatan Kemenkes Malang)



Article Info

Publish Date
19 Jul 2018

Abstract

PENENTUAN KADMIUM MENGGUNAKAN METODE PAPER ANALYTICAL DEVICE (PAD) DENGAN TEKNIK PENCITRAAN DIGITAL DALAM SAMPEL MAKANANABSTRAKKadmium merupakan salah satu logam berat dari sepuluh bahan kimia berbahaya dan menjadi perhatian kesehatan masyarakat. Kadmium (Cd(II)) bukan merupakan logam esensial dalam tubuh manusia maupun tumbuhan dan hewan yang berdampak kronis bagi kesehatan dan lingkungan. Berbagai metode telah banyak dikembangkan untuk mendeteksi kandungan kadmium dalam berbagai sampel. Salah satu metode yang dipelajari adalah paper analytical device berbasis kompleks Alizarin Red S. dengan analisis menggunakan teknik pencitraan digital. Metode ini menggunakan kertas Whatmann sebagai media sampel dan reagen pengkelat yang akan menghasilkan warna kuning sehingga dapat dianalis secara kolorimetri. Tujuan penelitian ini adalah menentukan kandungan Cd(II) dalam sampel makanan dengan metode PAD berbasis kompleks Alizarin Red S. Penelitian dilakukan di Laboratorium Kimia-Farmasi Universitas Ma Chung pada bulan Agustus-November 2017. Sampel yang digunakan adalah daun kangkung, ikan segar mujaer, lele, dan pindang tongkol dengan hasil analisis Cd(II) (mg/g)  masing – masing secara berurutan adalah 0.139; 0.210; 0.341 0.409. Hasil pengujian metode ini juga dibandingkan dengan metode standar AAS (Atomic Absorption Spectrometer).Kata kunci: kertas, kadmium, makanan, pencitraan, digital   DETERMINATION OF KADMIUM USING PAPER ANALYTICAL DEVICE (PAD) METHOD WITH DIGITAL IMAGING TECHNIQUE IN FOOD SAMPLEABSTRACTCadmium is one of a heavy metal from ten chemicals of major public health concern. Cadmium is not essential metal in the human body as well as animals, plants which acquire chronic impact for heath and the environment. Many methods have been developed to detect trace Cd(II) in various sample. One of that method is paper analytical device based on Alizarin Red S complex using digital color image analysis. The method used Whatmann Paper as a media sample and chelating reagents which produce yellow color complex that can analyze colorimetry. The purpose of this research of determination Cd(II) in food samples using PAD based on Alizarin Red S complex. The experiment was conducted at the Chemical-Pharmaceutical Laboratory, Ma Chung University in August-November 2017. Samples are convolvulus leaves, fresh fish like mujaer, catfish, cobs with the results of Cd(II) (mg/g) of each sample of 0.139; 0.210; 0.341 0.409 respectively. The result of the proposed methods is compared with standard method of AAS (atomic absorption spectrometer).Keywords : paper, cadmium, food, digital, color

Copyrights © 2018






Journal Info

Abbrev

JIS

Publisher

Subject

Agriculture, Biological Sciences & Forestry Biochemistry, Genetics & Molecular Biology Chemistry Computer Science & IT Mathematics Physics

Description

Jurnal Ilmiah Sains (Journal of Scientific Sciences) is the Journals Published by Faculty of Mathematics and Natural Sciences, Sam Ratulangi University. Jurnal Ilmiah Sains Published Twice a Year, i.e April and October. Jurnal Ilmiah Sains  welcomes full research articles in the area of ...