Atom Indonesia Journal
Vol 48, No 2 (2022): August 2022

Investigation of Electron Contamination on Flattened and Unflattened Varian Clinac iX 6X and 15X Photon Beam Based on Monte Carlo Simulation

F. Haryanto (Department of Physics, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Jl.Ganesa 10, Bandung 40116, Indonesia)
M. F. Rhani (Department of Radiology, Tan Tock Seng Hospital (TTSH), 11 Jalan Tan Tock Seng 308433, Singapore)
C. Anam (Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto, Semarang 50275, Indonesia)
S. Yani (Department of Physics, Faculty of Mathematics and Natural Sciences, IPB University (Bogor Agricultural University), Jl. Meranti IPB Dramaga, Bogor 16680, Indonesia)



Article Info

Publish Date
19 Aug 2022

Abstract

The aim of this study was to characterize electron contamination of a flattened (FF) and an unflattened (FFF) Varian Clinac iX 6X and 15X photon beams using Monte Carlo (MC) simulation. EGSnrc MC technique was used to model the flattened and unflattened head and simulate dose distribution of 6X and 15X of FF and FFF photon beam in water phantom. The materials and geometrical data of FF linac were provided by Tan Tock Seng Hospital (TTSH) Singapore. The FFF linac was modeled by removing the flattening filter component in the FF linac. Phase space files were scored after flattening filter and in the phantom surface. The phsp files were analyzed to characterize the particles produced by the linac head using BEAMDP. The contaminants contribute around 1 % and 2 % in the phsp1 for flattened and unflattened beams, respectively. The photons are scattered in small-angle in the range of 0 – 4o. The contaminant electron contributes up to one hundredth compared to the photons. The increase of field area affects the increase in contaminants and penumbra width due to the increasing number of particle scattered out of the field area. The unflattened beam affects the increase in the number of electron contamination and surface dose. The penumbra width of the flattened beams was smaller than the unflattened beams for the same field size and energy.

Copyrights © 2022






Journal Info

Abbrev

aij

Publisher

Subject

Materials Science & Nanotechnology

Description

Exist for publishing the results of research and development in nuclear science and technology Starting for 2010 Atom Indonesia published three times a year in April, August, and December The scope of this journal covers experimental and analytical research in all areas of nuclear science and ...