INDONESIAN JOURNAL OF MEDICAL LABORATORY SCIENCE AND TECHNOLOGY
Vol 5 No 1 (2023): Step up to strengthen the laboratory system and prepare for patients care

Analysis of APTT Based Clot Waveform Parameters in Various Clinical Conditions – A Study at A Tertiary Care Center

Rachana Lakhe (Department of pathology, Bharati Vidyapeeth Deemed to be University and Medical College, Pune, India)
Amit Nisal (Department of pathology, Bharati Vidyapeeth Deemed to be University and Medical College, Pune, India)
Preeti Doshi (Department of pathology, Bharati Vidyapeeth Deemed to be University and Medical College, Pune, India)
Ravindra Nimbargi (Department of pathology, Bharati Vidyapeeth Deemed to be University and Medical College, Pune, India)



Article Info

Publish Date
28 Apr 2023

Abstract

Various coagulation tests like Prothrombin Time (PT) and Activated Partial Thromboplastin Time (APTT) are estimated by automated coagulation analyzers. The newer fully automated analyzers generate clot wave forms aPTT-CWA for these parameters are derived. In this study, the objective was to analyze clot wave form characteristics morphology and its first and second derivative values in cases with abnormal APTT. ACL TOP 300 generated curves for APTT in a total 125 patients with 20 normal controls are included. First derivative, second derivative, morphology of curve: sigmoid, biphasic, prolonged pre-coagulation phase, second derivative morphology like early and late shoulder, biphasic peak, delayed deceleration were the analyzed parameters. Wave clot forms of 125 patients were included in this study. Patients (M:F - 2.2:1, mean age: 46.9 ± 20 years). A spectrum of clinical conditions was Covid (20%), liver disease (23%), polytrauma (10.4%), cardiac diseases (8.8%), sepsis/DIC (7.2%), thromboembolism (7.2%), renal diseases (6.4%), bacterial infections (4%), dengue (4%), snake bite (1.6%) and factor deficiency (1.6%). Liver and heart disease showed a significant difference in acceleration and deceleration peaks followed by sepsis, dengue, polytrauma and sepsis/DIC. Deceleration peak was prolonged in patients of Covid (p<0.05). Sepsis and liver diseases showed prolonged first derivative peak (p<0.05). CWA is very easily available on all automated coagulation analyzers. It is inexpensive with fast turn round time. Both quantitative as well as qualitative informations such as velocity, acceleration of clot formation and wave pattern details were recorded. Our study highlights importance of quantitative and qualitative CWA parameters acquired by performing APTT test for the automated analyzers.

Copyrights © 2023






Journal Info

Abbrev

IJMLST

Publisher

Subject

Health Professions Social Sciences

Description

Contributions will be considered for publication in Indonesian Journal of Medical Laboratory Science and Tehnology (IJMLST) concern kind from research, involvement and theory to functioning matters, education and training. The very wide spectrum of its topics includes: dosimeter, instrument ...