Comparison of Lipid Fractions of Icteric Sample by Using Three Devices

Ummul Khair (Hasanuddin University Of Makassar)
Asvin Nurulita (Department of Clinical Pathology, Faculty of Medicine, Hasanuddin University/Dr. Wahidin Sudirohusodo Hospital, Makassar)
Darwati Muhadi (Department of Clinical Pathology, Faculty of Medicine, Hasanuddin University/Dr. Wahidin Sudirohusodo Hospital, Makassar)



Article Info

Publish Date
22 Nov 2019

Abstract

Lipid fraction assessment in laboratory includes cholesterol, HDL, LDL, Triglycerides. The icteric sample is characterized by elevated levels of bilirubin and darkness yellow sample color. This research was to determine the comparison of lipid fraction of icteric sample by using three devices. Cross-sectional study at Clinical Pathology Laboratory of Dr. Wahidin Sudirohusodo of Makassar. Comparison of lipid fraction of icteric samples against 3 (three) devices (Pentra, Biomajesty, Conelab) in period April - June 2018. Statistical analysis using SPSS program. Total sample of 50 indicated that cholesterol level by Biomajesty was lower than Pentra400 (p < 0.001), while the cholesterol level by Conelab was significantly lower than Pentra400 (p > 0.001), but not significantly different with Biomajesty (p < 0.05). HDL level by Biomajesty did not differ significantly with Pentra400 (p > 0.05). HDL level by Conelab were significantly lower than Pentra400 (p < 0.001) and Biomajesty (p < 0.01). HDL level by Biomajesty was smallest than Pentra and Conelab. LDL level by Biomajesty did not differ significantly with Pentra400 (p > 0.05) while LDL level by Conelab was significantly lower than Pentra400 (p < 0.001) and Biomajesty (p < 0.001). It can be seen that the range of TG by Biomajesty is smallest (more accurate) than Pentra400 and Conelab. TG level by Biomajesty was significantly lower than Pentra400 (p < 0.01) while TG level by Conelab was not significantly different than Pentra400 (p > 0.05), but it was significantly higher than Biomajesty (p < 0.001). The research shows that Biomajesty is an accurate device for the measurements of HDL, LDL, and TG of icteric samples, whereas Conelab is an accurate device for cholesterol measurement of icteric samples.  

Copyrights © 2019






Journal Info

Abbrev

patologi

Publisher

Subject

Biochemistry, Genetics & Molecular Biology Health Professions Medicine & Pharmacology Neuroscience

Description

Indonesian Journal of Clinical Pathology and Medical Laboratory (IJCPML) is a journal published by “Association of Clinical Pathologist” professional association. This journal displays articles in the Clinical Pathology and Medical Laboratory scope. Clinical Pathology has a couple of ...