Jurnal Energi Dan Manufaktur
Vol 6 No 01 (2023): April 2023

The Efektivitas-NTU dan Koefisien Perpindahan Panas Keseluruhan Alat Penukar Panas Barisan Pipa tanpa Sirip Susunan Staggered dan Aligned Orientasi untuk Pengeringan

Made Ricki Murti (Udayana University)



Article Info

Publish Date
19 Jun 2023

Abstract

This study has designed an unfinned tubular pipes heat exchanger that oriented for drying applications. Pipes bank with staggered and aligned arrangement by flowing two working fluids are the flue gas from LPG combustion and air as drying fluid. Heat exchange occurs from the flue gas of LPG as a hot fluid to the air flowing is cold fluid as heat receiver. Flue gas is produced by burning LPG in the combustion chamber and flowing through the inside of the pipes, while air flows on the outside surface of unfinned pipes. Variations are made on the mass flow rate of fuel consumption flowing into the combustion chamber and the air mass flow rate on the outer surface of pipes. Data taken are includes: air inlet and outlet temperatures at outside surface of heat exchanger pipes, flue gas inlet and outlet temperatures inside surface of heat exchanger pipes, air flow velocity, flue gas flow velocity, and mass flow rate of fuel consumption. The performance that analyzed are includes: Heat Exchanger effectiveness, NTU, and overall heat transfer coefficient. From the results can be concluded that the average of performance values on staggered pipes bank arrangement is higher than aligned pipes bank arrangement. On the variation of the mass flow rate of fuel consumption that flow at the inner surface of the rows of pipes, it produces the maximum effectiveness value of 89.18% for the staggered arrangement and 86.26% for the aligned arrangement, that occurs at the mass flow rate of 0.033gram/s, the maximum NTU value of 2.11 for the staggered arrangement and 1.99 for the aligned arrangement, that occurs at mass flow rate of 0.027gram/s, and the maximum overall heat transfer coefficient of 27.56 W/m2.K for the staggered arrangement and 25, 99 W/m2.K for the aligned arrangement, that occurs at the mass flow rate of 0.04gram/s. On variation of the air mass flow rate that flows at outer surface of the rows of pipes, the staggered arrangement produces the maximum effectiveness value of 95.4%, the maximum NTU value of 2.37, and the maximum overall heat transfer coefficient value of 28.16 W/m2.K and all of them occurs at the air mass flow rate of 0.028 kg/s.

Copyrights © 2023






Journal Info

Abbrev

jem

Publisher

Subject

Energy Industrial & Manufacturing Engineering

Description

"Jurnal Energi dan Manufaktur" is a journal published by Department of Mechanical Engineering, University of Udayana, Bali since 2006. During 2006-2011 the journal's name was "Jurnal Ilmiah Teknik Mesin CAKRAM" (Scientific journal in mechanical engineering, CAKRAM). "Jurnal Energi dan Manufaktur" is ...