Jurnal Kendali Teknik dan Sains
Vol. 2 No. 3 (2024): Juli : Jurnal Kendali Teknik dan Sains

Optimasi Dosis Koagulan Aluminium Sulfat Al2 (SO4)3 Pada Ipam PT Hanarida Tirta Birawa Sidoarjo

Nursinta Abadiyah (Unknown)
Yayok Suryo Purnomo (Unknown)



Article Info

Publish Date
07 Jun 2024

Abstract

In drinking water treatment plants, there is a coagulation unit that requires coagulant substances. Coagulant dosage determination can be done using the jartest method. By carrying out a jar test, the correct dose will be known so that the coagulation process runs well, and the use of coagulants can be optimized. This research was carried out by analyzing jartest results from the company's internal laboratory for one week with two variations in jartest times in one day. The raw water used comes from shipping rivers with a company production capacity of 500 l/second. The dosage of Aluminum Sulphate coagulant used in the field is 165 mg/l, while the jastest results show that the optimum dosage is 140 mg/l. This research is expected to provide scientific information regarding determining coagulant dosage at IPAM PT Hanarida Tirta Birawa which makes it easier for installation operators.

Copyrights © 2024






Journal Info

Abbrev

jkts-widyakarya

Publisher

Subject

Computer Science & IT

Description

Jurnal ini meliputi pengetahuan dan informasi riset atau aplikasi riset dan pengembangan terkini dalam bidang teknologi. Ruang lingkup meliputi bidang Informatika, Teknik Mesin, Teknik Elektro,Teknik Sipil, Teknik Industri, Ilmu Komputer dan ...