PROSIDING SEMINAR NASIONAL FISIKA (E-JOURNAL)
Vol. 12 (2024): PROSIDING SEMINAR NASIONAL FISIKA (E-JOURNAL) SNF2023

KARAKTERISASI DAN PENGUJIAN SENSOR MQ-4 DAN MG-811 UNTUK PENGEMBANGAN SISTEM MONITORING KONSENTRASI GAS METANA DAN KARBON DIOKSIDA DI UDARA

Ramadhani, I Gusti Ayu Isnaini Fatha (Unknown)
Indrasari, Widyaningrum (Unknown)
Suhendar, Haris (Unknown)
Marpaung, Mangasi Alion (Unknown)



Article Info

Publish Date
31 Jan 2024

Abstract

Abstrak Seiring dengan perkembangan zaman, berbagai kegiatan indrustrialisasi dan urbanisasi dapat memicu peningkatan gas CH4 dan CO2 yang dapat memperburuk kualitas udara di lingkungan. Salah satu upaya untuk mengetahui kualitas udara adalah dengan melakukan monitoring konsentrasi gas di udara. Konsentrasi gas CH4 di udara dapat diukur menggunakan sensor MQ-4 sedangkan gas CO2 diukur menggunakan sensor MG-811. Dalam penggunaannya, perlu dilakukan karakterisasi sensor dan pengujian sensor dengan tujuan untuk mendapatkan persamaan kalibrasi, kesalahan relatif pengukuran, dan rentang kerja dari masing-masing sensor. Maka pada penelitian ini dilakukan proses karakterisasi sensor dengan membandingkan hasil keluaran sensor MQ-4 dengan CH4 Analyzer G2203 dan sensor MG-811 dengan CO2 Analyzer G2301 Picarro. Adapun hasil karakterisasi menunjukkan bahwa sensor MQ-4 memiliki kesalahan relatif rata-rata sebesar 0,066%. Sedangkan sensor MG-811 memiliki kesalahan relatif rata-rata sebesar 0,047%. Sedangkan pengujian sensor dilakukan dengan melakukan pengukuran sampel berupa asap kendaraan bermotor menggunakan variasi waktu. Adapun hasil pengujian menunjukkan bahwa sensor MQ-4 dapat bekerja dengan baik dalam rentang 1,885-1,914 PPM, sedangkan sensor MG-811 dapat bekerja dengan baik dalam rentang 406,311-409,169 PPM. Hasil tersebut selanjutnya akan digunakan dalam pengembangan sistem monitoring konsentrasi gas CH4 dan CO2 di udara. Kata-kata kunci: metana, karbon dioksida, MQ-4, MG-811, konsentrasi gas. Abstract Along with times, various industrialization and urbanization activities can trigger an increase in CH4 and CO2 gases which can improve air quality in environment. One effort to determine air quality is to monitor gas concentrations in air. Concentration of CH4 gas in air can be measured using MQ-4 sensor and CO2 gas is measured using MG-811 sensor. In use, it is necessary to characterize sensors and test sensors with aim of obtaining measured equations, relative measurement errors, and working distance of each sensor. So, in this research sensor characterization process was carried out by comparing output results of MQ-4 sensor with CH4 Analyzer G2203 and MG-811 sensor with CO2 Analyzer G2301 Picarro. Characterization results show that MQ-4 sensor has an average relative error of 0,066% and MG-811 sensor has an average relative error of 0,047%. While sensor testing is done by measuring samples in form of motorized vehicle smoke using time variations. The sensor testing results show that The MQ-4 sensor can work well in range of 1,885-1,914 PPM, while MG-811 sensor can work well in range of 406,311-409,169 PPM. These results will then be used in development of a monitoring system for CH4 and CO2 gases concentrations in air. Keywords: methane, carbon dioxide, MQ-4, MG-811, gas concentration.

Copyrights © 2024






Journal Info

Abbrev

prosidingsnf

Publisher

Subject

Electrical & Electronics Engineering Energy Physics Other

Description

Focus and Scope: Physics education Physics Instrumentation and Computation Material Physics Medical Physics and Biophysics Physics of Earth and Space Physics Theory, Particle, and Nuclear Environmental Physics and Renewable ...