Prosiding Seminar Nasional Inovasi Teknologi Terapan
Vol. 5 (2025): Prosiding Seminar Nasional Inovasi Teknologi Terapan

PENGUJIAN PROSES BALANCING PADA BLOWER

Syaputra Arianto, Handika (Unknown)
Zulfiandi, Wendi (Unknown)
Sateria, Angga (Unknown)
Hasdiansah, Hasdiansah (Unknown)



Article Info

Publish Date
22 Aug 2025

Abstract

This article discusses the balancing process on a blower using the 4-run method and the balancer feature on the Vibroport 80. The initial vibration measurement of the blower was recorded at 2.28 mm/s, with the impeller weighing 2.5 kg. After adding a 50-gram trial weight at an angle of 0°, the resulting vibration was 0.956 mm/s RMS. At 120°, the vibration measured 2.99 mm/s, and at 240°, it increased to 3.64 mm/s. Based on the calculations performed, a correction weight of 150 grams was determined at an angle of 20°, successfully reducing the vibration to 0.965 mm/s RMS. Using the balancer feature method, the initial vibration value of 1.91 mm/s gradually decreased to 1.36 mm/s after six stages of correction weight application. From the results of both tests, the 4-run method was found to be the most effective for balancing the blower

Copyrights © 2025






Journal Info

Abbrev

snitt

Publisher

Subject

Computer Science & IT Electrical & Electronics Engineering Mechanical Engineering

Description

Seminar Nasional Inovasi Teknologi Terapan (SNITT) dikelola oleh Politeknik Manufaktur Negeri Bangka Belitung sebagai wadah rutin bagi sivitas akademika dalam berbagi pengetahuan, temuan, dan pengalaman dalam hal inovasi teknologi terapan yang berkelanjutan. SNITT ini merupakan ajang seminar ilmiah ...