Journal of Computing Theories and Applications
Vol. 3 No. 2 (2025): in progress

Hybrid Dynamic Programming Healthcare Cloud-Based Quality of Service Optimization

Sitlong, Nengak I. (Unknown)
Evwiekpaefe, Abraham E. (Unknown)
Irhebhude, Martins E. (Unknown)



Article Info

Publish Date
26 Sep 2025

Abstract

The integration of Internet of Things (IoT) with cloud computing has revolutionized healthcare systems, offering scalable and real-time patient monitoring. However, optimizing response times and energy consumption remains crucial for efficient healthcare delivery. This research evaluates various algorithmic approaches for workload migration and resource management within IoT cloud-based healthcare systems. The performance of the implemented algorithm in this research, Hybrid Dynamic Programming and Long Short-Term Memory (Hybrid DP+LSTM), was analyzed against other six key algorithms, namely Gradient Optimization with Back Propagation to Input (GOBI), Deep Reinforcement Learning (DRL), improved GOBI (GOBI2), Predictive Offloading for Network Devices (POND), Mixed Integer Linear Programming (MILP), and Genetic Algorithm (GA) based on their average response time and energy consumption. Hybrid DP+LSTM achieves the lowest response time (82.91ms) with an energy consumption of 2,835,048 joules per container. The outcome of the analysis showed that Hybrid DP+LSTM have significant response times improvement, with percentage increases of 89.3%, 79.0%, 83.8%, 97.0%, 99.8%, and 99.94% against GOBI, GOBI2, DRL, POND, MILP, and GA, respectively. In terms of energy consumption, Hybrid DP+LSTM outperforms other approaches, with GOBI2 (3,664,337 joules) consuming 29.3% more energy, DRL (2,973,238 joules) consuming 4.9% more, GOBI (4,463,010 joules) consuming 57.4% more, POND (3,310,966 joules) consuming 16.8% more, MILP (3,005,498 joules) consuming 6.0% more, and the GA (3,959,935 joules) consuming 39.7% more. The result of ablation of the Hybrid DP+LSTM model achieves a 47.05% improvement over DP-only (156.57ms) and a 70.64% improvement over LSTM-only (282.41ms) in response time. On the energy efficiency side, Hybrid DP+LSTM shows 22.80% improvement over LSTM-only (3,671,51 joules), but 7.34% underperformance compared to DP-only (2,640,93). These research findings indicate that the Hybrid DP+LSTM technique provides the best trade-off between response time and energy efficiency. Future research should further explore hybrid approaches to optimize these metrics in IoT cloud-based healthcare systems.

Copyrights © 2025






Journal Info

Abbrev

jcta

Publisher

Subject

Computer Science & IT Decision Sciences, Operations Research & Management

Description

Journal of Computing Theories and Applications (JCTA) is a refereed, international journal that covers all aspects of foundations, theories and the practical applications of computer science. FREE OF CHARGE for submission and publication. All accepted articles will be published online and accessed ...