Analisis Faktor-faktor Yang Mempengaruhi Mutu Beton Ready Mix

Suri, Yola Andara Pratami (Unknown)
Noorhidana, Vera Agustriana (Unknown)
Helmi, Masdar (Unknown)
Isneini, Muhammad (Unknown)
Wahono, Endro Prasetyo (Unknown)



Article Info

Publish Date
25 Mar 2024

Abstract

Abstrak Batching Plant sebagai pengolah beton ready mix untuk pembangunan jalan. Dahulu terjadi penurunan mutu beton laboratorium dan lapangan. Akhirnya melatar belakangi penelitian dengan tujuan menganalisis faktor penyebab penurunan mutu seperti; standarisasi SNI material, waktu tempuh beton ke lapangan, perlakuan sampel, komposisi beton. Langkah yang digunakan ialah pengujian material, uji slump dan suhu campuran di laboratorium dan lapangan, mencatat waktu perjalanan dan tuang beton, pembuatan sampel lapangan dan laboratorium, pembuatan sampel khusus, pengujian kuat tekan beton mutu fc10 MPa dan kuat tarik lentur beton mutu Fs4,5 MPa usia 7 dan 28 hari, menggunakan Statistical Quality Control (SQC). Hasil kuat tekan dan kuat tarik lentur sampel laboratorium dan lapangan tidak konstan bahkan berada dibawah nilai (LCL). Penyebabnya pasir dengan kadar lumpur diatas 5%. Mengatasinya dengan penambahan Admixture, admixture Naptha E-121 0,9% menjadi 1,2%, Naptha RD-31 0,2% sampel balok dan Naptha E-121 0,3% menjadi 0,6%, Naptha RD-31 0,2% silinder. Kata kunci: Beton, Statistical Quality Control, Admixture  Abstract Batching Plant as a readymix concrete processor for road construction. In the past, there was a decline in the quality of laboratory and field concrete. Finally, the background for research with the aim of analyzing the factors causing quality decline such as; SNI standardization of materials, concrete travel time to the field, sample treatment, concrete composition. The steps used are material testing, slump testing and mixture temperature in the laboratory and field, recording travel and pouring times for concrete, making field and laboratory samples, making special samples, testing the compressive strength of FC'10 MPa quality concrete and the flexural tensile strength of Fs quality concrete. '4.5 MPa aged 7 and 28 days, using Statistical Quality Control (SQC). The results of the compressive strength and flexural tensile strength of laboratory and field samples are not constant and are even below the (LCL) value. The cause is sand with a mud content above 5%. Overcome this by adding admixture, admixture Naptha E-121 0.9% to 1.2%, Naptha RD-31 0.2% for beam samples and Naptha E-121 0.3% to 0.6%, Naptha RD-31 0 .2% cylinder. Keywords: Concrete, Statistical Quality Control, Admixture

Copyrights © 2024






Journal Info

Abbrev

teras

Publisher

Subject

Civil Engineering, Building, Construction & Architecture Engineering Environmental Science

Description

Teras Jurnal is a journal that communicates the results of research within the scope of civil engineering and scientific development as well as aspects of practitioners. The process of manuscript submission is open throughout the year. All submitted manuscript will be screened with double-blind peer ...