Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics
Vol. 4 No. 1 (2022): February

Vital Signs Monitoring Device with BPM and SpO2 Notification to the Internet of Things Based on Telegram App

Luthfiyah, Sari (Unknown)
Ramadhani, Elga Rahmah (Unknown)
Indrato, Tri Bowo (Unknown)
Wongjan, Anan (Unknown)



Article Info

Publish Date
17 Aug 2025

Abstract

Vital signs are an important component of monitoring the adult or child patient’s progress during hospitalization, as they allow for the prompt detection of delayed recovery or adverse events. Vital signs are measured to obtain basic indicators of a patient’s health status. The most common intervention performed in hospital medicine is a measurement of vital signs and these traditionally consist of blood pressure, temperature, pulse rate, and respiratory rate. Advanced monitoring systems incorporate a balanced combination of clinical and technological aspects to give an innovative healthcare outcome. Remote patient monitoring systems are rapidly becoming the core of healthcare deliveries. The paradigm shifted from traditional and manual recording to computer-based electronic records and further to smartphones as versatile and innovative healthcare monitoring systems. The purpose of this research is to design a Vital Sign Monitoring device for BPM and SpO2 Parameters with Notifications through the IoT-Based Telegram application. This device can monitor vital signs, especially BPM and SPO2 wherever the patient is and whenever, so that doctors or health workers, as well as patients, can find out their health condition. This display can be viewed via web thinger.io, then forwarded to telegram if an abnormal patient condition is found and there is an indicator light that will light up differently for each condition. This study uses the MAX30100 which is a digital sensor to detect oxygen saturation and heart rate. The results of this study have succeeded in displaying data on the IoT web and sending notifications to the Telegram application. And also, the resulting data has an error that does not exceed the allowable limit according to each parameter. The difference between heart rate readings and oxygen saturation values ​​on the device and patient monitor is 0.015% for heart rate and 0.01% for oxygen saturation.

Copyrights © 2022






Journal Info

Abbrev

ijeeemi

Publisher

Subject

Computer Science & IT Control & Systems Engineering Decision Sciences, Operations Research & Management Electrical & Electronics Engineering Health Professions Materials Science & Nanotechnology

Description

Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics (IJEEEMI) publishes peer-reviewed, original research and review articles in an open-access format. Accepted articles span the full extent of the Electronics, Biomedical, and Medical Informatics. IJEEEMI seeks to ...