Dinamika Teknik Mesin : Jurnal Keilmuan dan Terapan Teknik Mesin
Vol 8, No 1 (2018): Dinamika Teknik Mesin: Jurnal Keilmuan dan Terapan Teknik Mesin

Heat loss from hot water flowing in a copper pipe insulated using air enclosed with a PVC pipe

Albayani, A. (Unknown)
Mirmanto, M. (Unknown)
Syahrul, S. (Unknown)



Article Info

Publish Date
01 Jan 2018

Abstract

This paper presents investigations of heat loss from hot water flowing in an insulated copper pipe. Investigations were performed to know the heat loss from a copper pipe insulated using air enclosed with a PVC pipe. The fluid temperature used was kept at approximately 75°C in the entrance and its mass flow rate was around 12 g/s. The nominal copper pipe diameter was 6.35 mm; while the diameters of the PVC pipe were ranging from 12.7 mm to 5.08 mm. The length of the test section was approximately 3000 mm. The results show that the biggest heat loss is found using the bare copper pipe. When the copper pipe is insulated using air enclosed with a PVC pipe, the heat loss decreases with the increased PVC pipe diameters. The trend of the heat loss agrees with the critical insulation diameter theory.

Copyrights © 2018






Journal Info

Abbrev

DTM

Publisher

Subject

Aerospace Engineering Automotive Engineering Mechanical Engineering Physics

Description

The Dinamika Teknik Mesin is a peer-reviewed academic journal which publishes originally research papers or simulation/computational articles in all aspect of Mechanical Engineering such as energy conversion, materials, design and production/ manufacturing. The Dinamika Teknik Mesin publishes in two ...