Contagion: Scientific Periodical Journal of Public Health and Coastal Health
Vol 8, No 1 (2026): CONTAGION

Risk Factors Associated with Sick Building Syndrome Among Workers in High-Rise Office Buildings

Widya Ayu Oktavia (Master in Environmental Health, Faculty of Public Health, Diponegoro University, Semarang)
Onny Setiani (Master in Environmental Health, Faculty of Public Health, Diponegoro University, Semarang)
Tri Joko (Master in Environmental Health, Faculty of Public Health, Diponegoro University, Semarang)
Sulistiyani Sulistiyani (Master in Environmental Health, Faculty of Public Health, Diponegoro University, Semarang)
Suhartono Suhartono (Master in Environmental Health, Faculty of Public Health, Diponegoro University, Semarang)



Article Info

Publish Date
30 Mar 2026

Abstract

Indoor air quality is one of the crucial aspects of the work environment. Poor workplace conditions not only reduce comfort and job satisfaction but also significantly affect work productivity. One clinical manifestation of poor office environmental quality is the emergence of Sick Building Syndrome (SBS). The etiology of SBS is multifactorial, involving complex interactions between physical environmental factors (temperature, humidity, particulate dust), chemical factors (VOCs, CO₂), and biological agents, as well as individual characteristics and psychosocial conditions. This study aimed to determine the risk factors associated with the occurrence of SBS among employees of the Central Java Provincial Archives and Library Office. This research employed an analytical observational approach with a cross-sectional design involving 93 employees as respondents. The results showed that the average indoor air quality measurements in the work areas were as follows: humidity 56.30%, temperature 27.85oC, lighting intensity 170.04 lux, and air change per hour 3.43 times/hour. The prevalence of SBS among employees was 58.1%. There was not a significant association between temperature (p=0.035; RP=1.840), humidity (p=0.085; RP=0.712), lighting (p=0.121; RP=0.733), and ACH (p=0.791; RP=1.088) with SBS. In conclusion, this study identified no relationship between indoor air quality and the incidence of SBS among employees of the Central Java Provincial Archives and Library Office. Keywords:  Indoor Air Quality, Sick Building Syndrome, Risk Factors, Workers.

Copyrights © 2026






Journal Info

Abbrev

contagion

Publisher

Subject

Health Professions Public Health

Description

Contagion: Scientific Periodical Journal of Public Health and Coastal Health, A Scientific Periodic Journal of Public Health published by the Public health Study Program of The Faculty of Public Health UINSU Medan. This Journal prioritiez the collaboration of lecturers and students with scope of the ...