Jurnal Imejing Diagnostik
Vol 2, No 1: January 2016

Analisis Informasi Citra Anatomi antara Teknik Breath-Hold dan Trigger pada Pemeriksaan Magnetic Resonance Cholangiopancreatography (MRCP) Menggunakan Sequence T2 Half Fourier Acquisition Single Shot TSE (HASTE) Coronal Slab

Yusron Adi Utomo (RS Gunung Jati Cirebon)
Bambang Satoto (RSUP dr Kariadi Semarang)
Rini Indrati (Politeknik Kesehatan Kemenkes Semarang)



Article Info

Publish Date
11 Jan 2016

Abstract

Background: There are two image acquisition techniques in MRCP examination, which are breath-hold and trigger technique. Acquisition process in breath hold occurs when the patient holds their breath, meanwhile trigger technique uses respiratory gatting that functioned to monitor patient’s respiration and the acquisition occurs in the transition phase of inspiration and expiration. In Royal Taruma Jakarta Hospital this two technique are used sustainably, but in other hospital, such as Hasan Sadikin Bandung Hospital just uses one technique. This research aims to know the difference of anatomic image information of breath-hold and trigger technique in MRCP examination using T2 HASTE sequence coronal slab and to know which examination technique is better to produce anatomic image information between breath-hold and trigger technique.Methods: This research type was quantitative research with the observational approach. The data obtained by scanning 10 patients using breath-hold and trigger technique in Royal Taruma Jakarta Hospital. The image result was scored by radiology physician using checklist. The obtained data was analyzed with Wilcoxon test to know the difference of anatomic image information and which technique is better to produce anatomic image information between breath-hold and trigger technique.Results: The result showed that there were differences of anatomic image information of breath-hold and trigger technique on MRCP examination using T2 HASTE sequence coronal slab with p-value 0,011. Trigger technique produced better anatomic image information than breath-hold technique.Conclusion: There were differences of anatomic image information of breath hold and trigger technique on MRCP examination using T2 HASTE sequence coronal slab. Trigger technique produced better anatomic image information than breath-hold technique

Copyrights © 2016






Journal Info

Abbrev

jimed

Publisher

Subject

Health Professions Medicine & Pharmacology

Description

Jurnal Imejing Diagnostik (JImeD) memuat tulisan ilmiah dalam bidang radiologi berupa hasil penelitian dan non penelitian (konseptual). Jurnal Imejing Diagnostik (JImeD) terbit 2 kali dalam satu tahun yaitu pada bulan Januari dan Juli oleh Jurusan Teknik Radiodiagnostik dan Radioterapi, Politeknik ...