Lumina: Indonesian Journal of Neurology
Vol. 1 No. 3 (2025): December: Lumina: Indonesian Journal of Neurology

Carotid Endarterectomy Versus Carotid Artery Stenting With Double-Layer Micromesh Stent in Carotid Angioplasty: Network Meta-Analysis

Evelyn Natalie Hailianto (Universitas Pelita Harapan)
Fransiska Livia (Universitas Pelita Harapan)
Jesselyne Aurelia Santoso Kho (Universitas Pelita Harapan)
Clayton Christopher Hermawan (Universitas Pelita Harapan)
Jason Michael Prawira (Universitas Pelita Harapan)
Julius July (Universitas Pelita Harapan)



Article Info

Publish Date
30 Dec 2025

Abstract

Introduction: Carotid endarterectomy (CEA) remains the gold standard for carotid stenosis, but modern carotid artery stenting (CAS) with double-layer micromesh stents (e.g., CGuard, Roadsaver [RS]) offers potential reductions in peri-procedural embolic risk. However, comparative evidence between CEA and modern CAS remains limited. Methods: A systematic search of PubMed, ScienceDirect, and Europe PMC (June 23,2025) identified randomized and observational studies on symptomatic or high grade asymptomatic carotid stenosis using terms including “double-layer stent,” “micromesh,” “Roadsaver,” “CGuard,” and “carotid endarterectomy.” Reviews, meta analyses, and case reports were excluded. Comparisons included single-layer CAS vs. CEA, single-layer CAS vs. CGuard/RS, and indirect CEA vs. CGuard/RS. Outcomes were neurological complications and neurological death. Study quality was assessed using Cochrane RoB 2.0 and Newcastle-Ottawa Scale (NOS). A frequentist random effects network meta-analysis was performed using MetaInsight. Results: Eleven studies (7 RCTs, 4 observational; n=9483) were included. Seven had moderate RoB 2.0 risk, while three observational studies had fair quality and one study had good quality according to NOS. No significant difference was detected in neurological complications between CEA and CGuard/RS (OR 0.79; 95% CI 0.34-1.80), and neurological death was similar among CEA, CGuard/RS, and CAS. When compared with conventional CAS, CEA (OR 0.90; 95% CI 0.69–1.18) and CGuard/RS (OR 1.04; 95% CI 0.30–3.65) showed no significant differences. The direct comparison between CEA and CGuard/RS also demonstrated no significant effect (OR 0.86; 95% CI 0.24–3.11).Conclusions: This study found no significant differences in stroke prevention or safety CEA and DLMS. Larger comparative studies are required to establish their relative clinical effectiveness.Keywords: carotid artery stenting; carotid endarterectomy; micromesh stent; single layer stent; stroke

Copyrights © 2025






Journal Info

Abbrev

lumina

Publisher

Subject

Description

Focus and Scope Lumina: Indonesian Journal of Neurology is an open-access, peer-reviewed journal dedicated to advancing the field of neurological sciences, with a focus on both basic neuroscience and clinical neurology. The journal publishes original research, reviews, and intriguing case reports. ...