Evaluation of Well-Type Chamber Calibration Factor for Measurement of Ir-192 Brachytherapy Source Over 10 Institutions: Assef Firnando Firmansyah, Okky Agassy Firmansyah, Sri Inang Sunaryati, Nurman Rajagukguk

Assef Firnando Firmansyah Assef Firnando Firmansyah (Center for Technology of Safety and Radiation Metrology (PTKMR) BATAN Jl. Lebak Bulus Raya, Jakarta Selatan, 12440)
Okky Agassy Firmansyah Okky Agassy Firmansyah (Center for Technology of Safety and Radiation Metrology (PTKMR) BATAN Jl. Lebak Bulus Raya, Jakarta Selatan, 12440)
Sri Inang Sunaryati Sri Inang Sunaryati (Center for Technology of Safety and Radiation Metrology (PTKMR) BATAN Jl. Lebak Bulus Raya, Jakarta Selatan, 12440)
Nurman Rajagukguk Nurman Rajagukguk (Center for Technology of Safety and Radiation Metrology (PTKMR) BATAN Jl. Lebak Bulus Raya, Jakarta Selatan, 12440)



Article Info

Publish Date
08 May 2025

Abstract

This paper describes about the evaluation of well-type chamber calibration factor for measurement Ir-192 brachytherapy source. Data were collected at ten institutions that have modalities of Ir-192 brachytherapy. The well-type chamber measures the Ir-192 brachytherapy sources in terms of air kerma strength. Calibration was carried out using the substitution method which adopted from a protocol published by the International Atomic Energy Agency. The well-type chamber standard used was HDR-1000 Plus. The results obtained that NAKS for well-type chamber from PTW manufacturers have a range of values from 9.063 x 105 – 9.875 x 105Gy m2 h-1 A-1 with an average value 9.522 x 105Gy m2 h-1 A-1, while the well-type chamber from Standard Imaging manufacturers have a range of values from 4.634 x 105 – 4.662 x 105Gy m2 h-1 A-1 with an average value 4.648 x 105Gy m2 h-1 A-1. The range of deviations obtained between NAKS new and NAKS old ranges from 0.8% to -1.8%, while the range of normalization results of NAKS new to the average value of NAKS new ranges from 0.952 - 1.029. There was one calibration factor that has a deviation of more than 1% over the NAKS old. Based on the calculation of uncertainty, all the calibration factor results obtained were still within the accepted range.

Copyrights © 2020






Journal Info

Abbrev

jfa

Publisher

Subject

Physics

Description

JFA (Jurnal Fisika dan Aplikasinya, Abbreviation: J.Fis. dan Apl.) hanya menerbitkan artikel penelitian asli serta mengulas artikel tentang topik seputar bidang fisika (fisika teori, material, optik, instrumentasi, geofisika) dan aplikasinya. Naskah yang dikirimkan ke JFA belum pernah diterbitkan ...