JFA (Jurnal Fisika dan Aplikasinya)
Vol 15 No 1 (2019): January 2019 Edition

Synthesis and Corrosion Test of Magnesium Zinc-5% Hydroxyapatite (MgZn-5% wt.Hap) Biocomposites as a Bone Biodegradable Implant Material: Henni Sitompul, Kiagus Dahlan, Deni Noviana, Marzuki Silalahi, Sulistioso Giat Sukaryo, Yohanes Edi Gunanto

Henni Sitompul Henni Sitompul (Department of Physics Education, University of Pelita Harapan, Jl. M.H. Thamrin 1100 Lippo Karawaci Tengerang, Tangerang 15811)
Kiagus Dahlan Kiagus Dahlan (Faculty of Mathematics and Science, Bogor Agricultural University, Jl. Dramaga, Bogor 16680)
Deni Noviana Deni Noviana (Faculty of Veterinary Medicine, Bogor Agricultural University, Jl. Dramaga, Bogor 16680)
Marzuki Silalahi Marzuki Silalahi (National Nuclear Energy Agency of Indonesia, Kawasan PUSPIPTEK Serpong Gedung 43, Setu, Tangerang Selatan 15310)
Sulistioso G. Sukaryo Sulistioso G. Sukaryo (National Nuclear Energy Agency of Indonesia, Kawasan PUSPIPTEK Serpong Gedung 43, Setu, Tangerang Selatan 15310)
Yohanes E. Gunanto Yohanes E. Gunanto (Department of Physics Education, University of Pelita Harapan, Jl. M.H. Thamrin 1100 Lippo Karawaci Tengerang, Tangerang 15811)



Article Info

Publish Date
08 May 2025

Abstract

In recent years, development of magnesium (Mg) as biodegradable implant very rapidly in orthopedic applications. This is due to its young’s modulus close to young modulus of natural bone. However, Mg implants demonstrate higher biological activity which could cause high degradation rate in human bio-environment. Consequently, needed to develop Mg-based alloys with superior corrosion performance. In the present study, it has been attempted to develop biocomposite of Magnesium Zinc-5% Hydroxyapatite (MgZn-5%HAp) as biodegradable bone implant. The biocomposites were prepared by adding 5wt.% powders to MgZn powder and then were sintered at temperature 350 oC in vacuum furnace for holding an hour. The characterization of MgZn-5wt%HAp biocomposite was examined by Scanning Electron Microscopy with Energy Dispersive Spectroscopy (SEM/EDS) and X-ray diffraction (XRD) while corrosion tested by potensiostat. The SEM / EDS and XRD results indicated that some of the Zn atoms have dissolved in Mg to form a MgZn solid solution. The SEM results also showed that the MgZn-5%HAp biocomposite has a microstructure with a matrix Mg and HAp at the grain boundary. The presence of HAp in the sample resulted in a smaller crystallite size and corrosion rate compared to the one with MgZn alloy.

Copyrights © 2019






Journal Info

Abbrev

jfa

Publisher

Subject

Physics

Description

JFA (Jurnal Fisika dan Aplikasinya, Abbreviation: J.Fis. dan Apl.) hanya menerbitkan artikel penelitian asli serta mengulas artikel tentang topik seputar bidang fisika (fisika teori, material, optik, instrumentasi, geofisika) dan aplikasinya. Naskah yang dikirimkan ke JFA belum pernah diterbitkan ...