Jurnal Penelitian Kesehatan Suara Forikes
Vol 17, No 7 (2026): July 2026

Quality Control Analysis of 1.5 Tesla MRI Scanning Equipment at Sanjiwani Hospital Radiology Installation

Ida Bagus Candra Prabhawa (Department of Imaging Radiology, Akademi Teknik Radiodiagnostik dan Radioterapi Bali, Denpasar
guscandraprabhawa2001@gmail.com (Correspondence))

I Made Lana Prasetya (Department of Imaging Radiology, Akademi Teknik Radiodiagnostik dan Radioterapi Bali, Denpasar)
Ni Luh Putu Citra Larashati (Sanjiwani Gianyar Hospital, Gianyar)



Article Info

Publish Date
31 Jul 2026

Abstract

Magnetic Resonance Imaging (MRI) is an imaging modality that produces high-resolution anatomical images without the use of ionizing radiation. The quality of MRI images is influenced by the stability of the system, so the implementation of Quality Control (QC) is routinely needed to ensure image quality and support the accuracy of diagnosis. In hospitals with limited QC facilities, visual checklists and artifact evaluations are used as methods of monitoring system quality. This study aimed to analyze the implementation of Quality Control on the 1.5 Tesla MRI system at the Radiology Installation of Sanjiwani Hospital through visual checklist and artifact evaluation. This study was a descriptive observational study carried out at the Radiology Installation of Sanjiwani Hospital in February-March 2026. Data were obtained through direct observation of the implementation of QC, visual checklist assessment, and documentation of phantom image results. The data were analyzed descriptively. The results of the 30-day visual checklist showed that all parameters of the MRI system were functioning properly without any disturbances. Artifact evaluations conducted on February 26, 2026, March 5, 2026, March 12, 2026, and March 19, 2026 showed that no artifacts were found in the phantom image. Based on the guidelines of the American College of Radiology (ACR) 2015, phantom images appear round, homogeneous, symmetrical, without ghost images, abnormal shadows, or distortions. In conclusion, the implementation of Quality Control on the 1.5 Tesla MRI system at the Radiology Installation of Sanjiwani Hospital through visual checklist and artifact evaluation showed that the MRI system was operating well and had met the MRI Quality Control guidelines based on the 2015 ACR.Keywords: quality control; 1.5 Tesla MRI System; visual checklist; artefact evaluation

Copyrights © 2026






Journal Info

Abbrev

sf

Publisher

Subject

Health Professions Medicine & Pharmacology Nursing Public Health

Description

Journal of Health Research "Forikes Voice" is a medium for the publication of articles on research and review of the literature. We accept articles in the areas of health such as public health, medicine, nursing, midwifery, nutrition, pharmaceutical, environmental health, health technology, clinical ...