SDJ
VOLUME 4, ISSUE 1, JAN - APR 2020

Effect of Light Intensity, Light-Curing Unit Exposure Time, and Porcelain Thickness of IPS e.max press and Vintage LD Press on the Hardness of Resin Cement

Silvia Naliani (Program of Dental Science, Faculty of Dentistry, Trisakti University, West Jakarta, Indonesia)
Suzan Elias (Department of Prosthodontic, Faculty of Dentistry, Trisakti University, West Jakarta, Indonesia)
Rosalina Tjandrawinata (Department of Dental Material, Faculty of Dentistry, Trisakti University, West Jakarta, Indonesia)



Article Info

Publish Date
30 Dec 2025

Abstract

Background: Porcelain veneer restoration is the primary choice for indirect restoration, especially for anterior teeth, given its high esthetic properties and lower failure rate than resin composites. Glass-based ceramics such as IPS e.max Press and Vintage LD Press are a choice for veneer due to its superior physical properties. Resin cement is used to attach the veneer restoration to the teeth. The polymerization of resin cement used in veneer restoration affects the stability, mechanical properties, and resistance of the restoration. The composition and thickness of the porcelain material affect the light‑curing unit to cured resin cement. Objectives: The aim of this study was to evaluate the influence of porcelain thickness, light intensity, and exposure time in the hardness of resin cement. Methods: Porcelain samples measuring 5 mm in diameter with three types of thicknesses of IPS e.max Press and Vintage LD Press were used in the study. Resin cement in a metal mold was placed under a porcelain sample before curing with a light-emitting diode (LED) intensity of 1300 or 1700 mW/cm2. The hardness test was then carried out on the bottom of the resin cement. Result: The highest hardness value was obtained from a Vintage LD Press with a thickness of 0.7 mm (cured at 1300 mW/cm2 for 20 s). A four‑way ANOVA test showed significant differences for brands, thicknesses, and times of exposure (P < 0.05) as well as insignificant difference for LED intensity. Conclusion: The study indicates that polymerization of resin cement with lower thickness presented higher hardness values. Irradiation time affected hardness, while LED intensity did not.

Copyrights © 2020






Journal Info
SDJ

Abbrev

dental

Publisher

Subject

Description

Scientific Dental Journal (SDJ) aims to publish open-access, high quality, peer-reviewed original research and reviews in all aspects of dentistry and dental research. The journal will cover technical and clinical studies related to health, ethical and social issues in field dentistry. The major ...