SDJ
VOLUME 7, ISSUE 2, MAY - AUG 2023

The effect of surface treatment and post-length on fiber post-bond strength

Stevan Untono (Department of Conservative Dentistry, Faculty of Dentistry, Trisakti University, Jakarta, Indonesia)
Ade Prijanti Dwisaptarini (Department of Conservative Dentistry, Faculty of Dentistry, Trisakti University, Jakarta, Indonesia)
Aryadi Subrata (Department of Conservative Dentistry, Faculty of Dentistry, Trisakti University, Jakarta, Indonesia)
Rosalina Tjandrawinata (Department of Dental Materials, Faculty of Dentistry, Universitas Trisakti, Jakarta, Indonesia)



Article Info

Publish Date
01 Jan 2024

Abstract

Background: Endodontically treated teeth with extensive loss structure may require a post. Fiber post is made of a resin polymer matrix held by epoxy resin, which has a high conversion rate and high cross-linking, which may not interact with the monomer of resin cement that can reduce the bond strength that may cause post-debonding, which is a common failure of fiber post. Post-surface treatment and post-length are factors that affect post-bond strength. Objective: This study aims to determine the effect of surface treatment on fiber post and post-length on the bond strength of fiber post. Materials and Methods: Thirty mandibular premolars were selected, decoronated 15 mm from the coronal to the apical region, and then subjected to root canal treatment, obturation, and post-preparation. The samples were initially divided into two groups; each was assigned to a specific post-length; then, each group was randomly divided into a negative control group, air abrasion group, and laser group, for a total of six groups (n = 5). Self-adhesive resin cement is used for post-cementation. Selfadhesive resin cement is used for post-cementation. The evaluation of fiber postbond strength in this study was evaluated with the pull-out test using a universal testing machine at a speed of 0.5 mm/min. Data were analyzed by two-way ANOVA and Tukey’s test. Results: The air abrasion group showed a higher bond strength (P < 0.05) compared with the control and Er:Cr:YSGG laser groups. No significant difference in bond strength was observed between the control and Er:Cr:YSGG laser groups with both post-lengths. Moreover, post-length had no effect on bond strength, and no significant interaction was found between surface treatment and post-length. Conclusion: In this study, the bond strength was higher with surface treatment by air abrasion. Post-length had no impact on bond strength.

Copyrights © 2023






Journal Info
SDJ

Abbrev

dental

Publisher

Subject

Description

Scientific Dental Journal (SDJ) aims to publish open-access, high quality, peer-reviewed original research and reviews in all aspects of dentistry and dental research. The journal will cover technical and clinical studies related to health, ethical and social issues in field dentistry. The major ...